-
- Huihui Wang, Liang Zhang, and Xueren Teng.
- Qingdao Eighth People's Hospital, Qingdao, China.
- Medicine (Baltimore). 2024 Jan 19; 103 (3): e36484e36484.
BackgroundThe aim of this study was to compare the efficacy and safety of patient-specific instrumentation (PSI) and conventional instrumentation (CI) for unicompartmental knee arthroplasty. Our hypothesis was that the PSI would be superior to CI in improving implant positioning and clinical function.MethodsWe searched electronic databases (PubMed, Web of Science, Embase, and Cochrane) to identify relevant studies published before July 1, 2023 that met our inclusion criteria. The identified reports at least included one of the following outcome variables: coronal component alignment, sagittal component alignment, number of outliers, hip-knee-ankle angle, postoperative complications, operative time and knee joint functional evaluation. For dichotomous variables, we calculated the risk ratio and its 95% confidence interval (CI). For continuous variables, we calculated the mean difference (MD) and its 95% CI. Heterogeneity of the included studies was assessed using the standard chi-square test. Meta-analyses were performed using RevMan 5.4. software. The meta-analysis was registered with PROSPERO (No. CRD42023454160).ResultsA total of 9 articles were included in the analysis, consisting of 4 randomized controlled trials and 5 cohort studies. The study population comprised 494 patients, with 262 in the PSI group and 232 in the CI group. Our findings demonstrate that the PSI group exhibits superior tibial component coronal alignment compared to the CI group (MD = -0.66, 95% CI: -1.21 to -0.12, P = .02). Conversely, the CI group demonstrates better femoral component coronal alignment than the PSI group (MD = 0.89, 95% CI: 0.17-1.60, P = .01). No significant between 2 groups differences were observed in tibial component sagittal alignment, femoral component sagittal alignment, tibial coronal axis outliers, tibial sagittal axis outliers, femoral coronal axis outliers, femoral sagittal axis outliers, postoperative complications, operative time, hip-knee-ankle angle, and postoperative knee joint function score.ConclusionsOur study findings suggest that the PSI confer an advantage in achieving superior tibial component coronal alignment, whereas the CI associated with better femoral component coronal alignment. However, no significant differences were observed between the groups in terms of other parameters. Future studies with larger sample sizes are needed to validate these findings.Copyright © 2024 the Author(s). Published by Wolters Kluwer Health, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.