• Spine · Sep 2024

    Detection and Characterization of Endplate Structural Defects on CT: A Diagnostic Accuracy Study.

    • Aliyu Lawan, Andrew Leung, Stephanie Leung, James Faul, Joseph U Umoh, David W Holdsworth, Dianne M Bryant, and Michele C Battié.
    • Faculty of Health Sciences, School of Physical Therapy, and Western's Bone and Joint Institute, Western University, London, ON, Canada.
    • Spine. 2024 Sep 1; 49 (17): 121912261219-1226.

    Study DesignDiagnostic test study.ObjectiveTo determine the reliability and validity or diagnostic accuracy of two previously described endplate structural defect (EPSD) assessment methods.Summary Of Background DataStudies of EPSD may further the understanding of pathoanatomic mechanisms underlying back pain. However, clinical imaging methods used to document EPSD have not been validated, leaving uncertainty about what the observations represent.Materials And MethodsUsing an evaluation manual, 418 endplates on CT sagittal slices obtained from 19 embalmed cadavers (9 men and 10 women, aged 62-91 yr) were independently assessed by two experienced radiologists and a novice for EPSD using the two methods. The corresponding micro-CT (µCT) from the harvested T7-S1 spines were assessed by another independent rater with excellent intra-rater reliability (k=0.96).ResultsInter-rater reliability was good for the presence (k=0.60-0.69) and fair for specific phenotypes (k=0.43-0.58) of EPSD. Erosion, for which the Brayda-Bruno classification lacked a category, was mainly (82.8%) classified as wavy/irregular, while many notched defects (n=15, 46.9%) and Schmorl's nodes (n=45, 79%) were recorded as focal defects using Feng's classification. When compared to µCT, endplate fractures (n=53) and corner defects (n=28) were routinely missed on CT. Endplates classified as wavy/irregular on CT corresponded to erosion (n=29, 21.2%), jagged defects (n=21, 15.3%), calcification (n=19, 13.9%), and other phenotypes on µCT. Some focal defects on CT represented endplate fractures (n=21, 27.6%) on µCT. Overall, with respect to the presence of an EPSD, there was a sensitivity of 70.9% and a specificity of 79.1% using Feng's method, and 79.5% and 57.5% using Brayda-Bruno's method. Poor to fair inter-rater reliability (k=0.26-0.47) was observed for defect dimensions.ConclusionThere was good inter-rater reliability and evidence of criterion validity supporting assessments of EPSD presence using both methods. However, neither method contained all needed EPSD phenotypes for optimal sensitivity, and specific phenotypes were often misclassified.Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…