- Ling Peng, Long Zhao, Xue Zhang, Yi Zhang, Meng Ding, Zhibin Lin, Hao Jiang, Yuchen Huang, Bo Gao, and Wei Wei.
- Department of Anesthesiology, West China Hospital, Sichuan University, 37 Guo Xue Xiang, Chengdu, 610041, China.
- BMC Anesthesiol. 2024 Feb 6; 24 (1): 5353.
BackgroundContinuous and noninvasive hemoglobin (Hb) monitoring during surgery is essential for anesthesiologists to make transfusions decisions. The aim of this study was to investigate the feasibility and accuracy of noninvasive and continuous Hb monitoring using transesophageal descending aortic photoplethysmography (dPPG) in porcine model.MethodsNineteen landrace pigs, aged 3 to 5 months and weighing 30 to 50 kg, were enrolled in this study. A homemade oximetry sensor, including red (660 nm) and infrared (940 nm) lights, was placed in the esophagus for dPPG signal detection to pair with the corresponding reference Hb values (Hbi-STAT) measured by blood gas analysis. The decrease and increase changes in Hb concentration were achieved by hemodilution and transfusion. Metrics, including alternating current (AC), direct current (DC), and AC/DC for both red and infrared light were extracted from the dPPG signal. A receiver operating characteristic (ROC) curve was built to evaluate the performance of dPPG metrics in predicting the Hb "trigger threshold" of transfusion (Hb < 60 g/L and Hb > 100 g/L). Agreement and trending ability between Hb measured by dPPG (HbdPPG) and by blood gas analysis were analyzed by Bland-Altman method and polar plot graph. Error grid analysis was also performed to evaluate clinical significance of HbdPPG measurement.ResultsThe dPPG signal was successfully detected in all of the enrolled experimental pigs, without the occurrence of a continuous loss of dPPG signal for 2 min during the entire measurement. A total of 376 pairs of dPPG signal and Hbi-STAT were acquired. ACred/DCred and ACinf/DCinf had moderate correlations with Hbi-STAT, and the correlation coefficients were 0.790 and 0.782, respectively. The areas under the ROC curve for ACred/DCred and ACinf/DCinf in predicting Hbi-STAT < 60 g/L were 0.85 and 0.75, in predicting Hbi-STAT > 100 g/L were 0.90 and 0.83, respectively. Bland-Altman analysis and polar plot showed a small bias (1.69 g/L) but a wide limit of agreement (-26.02-29.40 g/L) and a poor trend ability between HbdPPG and Hbi-STAT. Clinical significance analysis showed that 82% of the data lay within the Zone A, 18% within the Zone B, and 0% within the Zone C.ConclusionIt is feasible to establish a noninvasive and continuous Hb monitoring by transesophageal dPPG signal. The ACred/DCred extracted from the dPPG signal could provide a sensitive prediction of the Hb threshold for transfusion. The Hb concentration measured by dPPG signal has a moderate correlation with that measured by blood gas analysis. This animal study may provide an experimental basis for the development of bedside HbdPPG monitoring in the future.© 2024. The Author(s).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.