-
Journal of neurosurgery · Aug 2022
Development of a miniaturized robotic guidance device for stereotactic neurosurgery.
- Georgi Minchev, Ayguel Wurzer, Wolfgang Ptacek, Gernot Kronreif, Alexander Micko, Christian Dorfer, and Stefan Wolfsberger.
- 1Department of Neurosurgery, Medical University Vienna; and.
- J. Neurosurg. 2022 Aug 1; 137 (2): 479488479-488.
ObjectiveConsistently high accuracy and a straightforward use of stereotactic guidance systems are crucial for precise stereotactic targeting and a short procedural duration. Although robotic guidance systems are widely used, currently available systems do not fully meet the requirements for a stereotactic guidance system that combines the advantages of frameless surgery and robotic technology. The authors developed and optimized a small-scale yet highly accurate guidance system that can be seamlessly integrated into an existing operating room (OR) setup due to its design. The aim of this clinical study is to outline the development of this miniature robotic guidance system and present the authors' clinical experience.MethodsAfter extensive preclinical testing of the robotic stereotactic guidance system, adaptations were implemented for robot fixation, software usability, navigation integration, and end-effector application. Development of the robotic system was then advanced in a clinical series of 150 patients between 2013 and 2019, including 111 needle biopsies, 13 catheter placements, and 26 stereoelectroencephalography (SEEG) electrode placements. During the clinical trial, constant modifications were implemented to meet the setup requirements, technical specifications, and workflow for each indication. For each application, specific setup, workflow, and median procedural accuracy were evaluated.ResultsApplication of the miniature robotic system was feasible in 149 of 150 cases. The setup in each procedure was successfully implemented without adding significant OR time. The workflow was seamlessly integrated into the preexisting procedure. In the course of the study, procedural accuracy was improved. For the biopsy procedure, the real target error (RTE) was reduced from a mean of 1.8 ± 1.03 mm to 1.6 ± 0.82 mm at entry (p = 0.05), and from 1.7 ± 1.12 mm to 1.6 ± 0.72 mm at target (p = 0.04). For the SEEG procedures, the RTE was reduced from a mean of 1.43 ± 0.78 mm in the first half of the procedures to 1.12 ± 0.52 mm (p = 0.002) at entry in the second half, and from 1.82 ± 1.13 mm to 1.57 ± 0.98 mm (p = 0.069) at target, respectively. No healing complications or infections were observed in any case.ConclusionsThe miniature robotic guidance device was able to prove its versatility and seamless integration into preexisting workflow by successful application in 149 stereotactic procedures. According to these data, the robot could significantly improve accuracy without adding time expenditure.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.