• Crit Care · Mar 2024

    Meta Analysis

    Accuracy of respiratory muscle assessments to predict weaning outcomes: a systematic review and comparative meta-analysis.

    • Diego Poddighe, Marine Van Hollebeke, Yasir Qaiser Choudhary, CamposDébora RibeiroDRDepartment of Internal Medicine, Ribeirão Preto Medical School, University of São Paulo (USP), Ribeirão Prêto, Brazil., Michele R Schaeffer, Jan Y Verbakel, Greet Hermans, Rik Gosselink, and Daniel Langer.
    • Department of Rehabilitation Sciences, Research Group for Rehabilitation in Internal Disorders, KU Leuven, 3000, Leuven, Belgium.
    • Crit Care. 2024 Mar 7; 28 (1): 7070.

    BackgroundSeveral bedside assessments are used to evaluate respiratory muscle function and to predict weaning from mechanical ventilation in patients on the intensive care unit. It remains unclear which assessments perform best in predicting weaning success. The primary aim of this systematic review and meta-analysis was to summarize and compare the accuracy of the following assessments to predict weaning success: maximal inspiratory (PImax) and expiratory pressures, diaphragm thickening fraction and excursion (DTF and DE), end-expiratory (Tdiee) and end-inspiratory (Tdiei) diaphragm thickness, airway occlusion pressure (P0.1), electrical activity of respiratory muscles, and volitional and non-volitional assessments of transdiaphragmatic and airway opening pressures.MethodsMedline (via Pubmed), EMBASE, Web of Science, Cochrane Library and CINAHL were comprehensively searched from inception to 04/05/2023. Studies including adult mechanically ventilated patients reporting data on predictive accuracy were included. Hierarchical summary receiver operating characteristic (HSROC) models were used to estimate the SROC curves of each assessment method. Meta-regression was used to compare SROC curves. Sensitivity analyses were conducted by excluding studies with high risk of bias, as assessed with QUADAS-2. Direct comparisons were performed using studies comparing each pair of assessments within the same sample of patients.ResultsNinety-four studies were identified of which 88 studies (n = 6296) reporting on either PImax, DTF, DE, Tdiee, Tdiei and P0.1 were included in the meta-analyses. The sensitivity to predict weaning success was 63% (95% CI 47-77%) for PImax, 75% (95% CI 67-82%) for DE, 77% (95% CI 61-87%) for DTF, 74% (95% CI 40-93%) for P0.1, 69% (95% CI 13-97%) for Tdiei, 37% (95% CI 13-70%) for Tdiee, at fixed 80% specificity. Accuracy of DE and DTF to predict weaning success was significantly higher when compared to PImax (p = 0.04 and p < 0.01, respectively). Sensitivity and direct comparisons analyses showed that the accuracy of DTF to predict weaning success was significantly higher when compared to DE (p < 0.01).ConclusionsDTF and DE are superior to PImax and DTF seems to have the highest accuracy among all included respiratory muscle assessments for predicting weaning success. Further studies aiming at identifying the optimal threshold of DTF to predict weaning success are warranted.Trial RegistrationPROSPERO CRD42020209295, October 15, 2020.© 2024. The Author(s).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…