-
Rev Assoc Med Bras (1992) · Jan 2024
Local imaging to interpret tumor size in F18 fluorodeoxyglucose positron emission tomography/CT in lung cancers.
- Şadiye Altun Tuzcu, İhsan Kaplan, İbrahim İbiloğlu, Ali Uyar, Fatih Güzel, Yunus Güzel, and Bekir Taşdemir.
- Dicle University Medical Faculty, Department of Nuclear Medicine - Diyarbakır, Turkey.
- Rev Assoc Med Bras (1992). 2024 Jan 1; 70 (2): e20230762e20230762.
ObjectiveThis study aimed to determine the thoracic and extra-thoracic extension of the disease in patients diagnosed with lung cancer and who had whole-body F18-fluorodeoxyglucose positron emission tomography/CT imaging and to investigate whether there is a relationship between tumor size and extrathoracic spread.MethodsA total of 308 patients diagnosed with lung cancer were included in this study. These 308 patients were first classified as group 1 (SPN 30 mm>longest lesion diameter ≥10 mm) and group 2 (lung mass (longest lesion diameter ≥30 mm), and then the same patients were classified as group 3 (nodular diameter of ≤20 mm) and group 4 (nodular size of >20 mm). Group 1 was compared with group 2 in terms of extrathoracic metastases. Similarly, group 3 was compared with group 4 in terms of frequency of extrathoracic metastases. F18 fluorodeoxyglucose positron emission tomography/CT examination was used to detect liver, adrenal, bone, and supraclavicular lymph node metastasis, besides extrathoracic metastasis.ResultsLiver, bone, and extrathoracic metastasis in group 1 was statistically lower than in group 2 (p<0.001, p<0.01, and p=0.03, respectively). Liver, extrathoracic, adrenal, and bone metastasis in group 3 was statistically lower than that in group 4 (p<0.001, p=0.01, and p=0.04, p<0.01, respectively). The extrathoracic extension was observed in only one patient in group 3. In addition, liver, adrenal, and bone metastases were not observed in group 3 patients.ConclusionPositron emission tomography/CT may be more appropriate for cases with a nodule diameter of ≤20 mm. Performing local imaging in patients with a nodule diameter of ≤20 mm could reduce radiation exposure and save radiopharmaceuticals used in positron emission tomography/CT imaging.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.