• Technol Health Care · Jan 2014

    PMMA-augmentation of incompletely cannulated pedicle screws: a cadaver study to determine the benefits in the osteoporotic spine.

    • H Goost, C Deborre, D C Wirtz, C Burger, A Prescher, C Fölsch, R Pflugmacher, and K Kabir.
    • Department of Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany.
    • Technol Health Care. 2014 Jan 1;22(4):607-15.

    BackgroundPedicle screw pullout due to poor bone quality, mainly caused by osteoporosis, is a common problem in spine surgery. Special implants and techniques, especially PMMA augmentation, were developed to improve the fixation of pedicle screws. PMMA injection into a pilot hole or through a screw involves the same risks as vertebroplasty or kyphoplasty, regardless of the technique used. Especially when using fully cannulated screws anterior leakage is possible.ObjectiveTo prove PMMA injection is safe and possible without leakage through an incompletely cannulated screw and also increases pullout forces in the osteoporotic vertebra.MethodsIncompletely cannulated pedicle screws were tested by axial pullout in human cadavers, divided into osteoporotic and non-osteoporotic groups. Non-augmented and PMMA-augmented pedicle screws were compared. Twenty-five human vertebrae were measured by DEXA and divided into osteoporotic and non-osteoporotic groups. In each vertebra both pedicles were instrumented with the new screw (WSI-Expertise 6×45 mm, Peter Brehm Inc. Germany); the right screw was augmented with a 3 mL PMMA injection through the screw. On each screw axial pullout was performed after X-ray and CT scan.ResultsRadiographs and CT scans excluded PMMA leakage. Cement was distributed in the middle and posterior third of the vertebrae. Pullout forces were significantly higher after pedicle screw augmentation, especially in the osteoporotic bone. All augmented pedicle screws showed higher pullout forces compared with the unaugmented screws.ConclusionsWe minimized the risk of leakage by using a screw with a closed tip. On the whole, PMMA augmentation through an incompletely cannulated pedicle screw is safe and increases pullout forces in osteoporotic bone to the level of healthy bone. Therefore the new incompletely cannulated screw can be used for pedicle screw augmentation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…