-
- Bas J J Bindels, Renée Hovenier, Olivier Q Groot, Koen L Vincken, Jan J Rongen, SmitsMaarten L JMLJDepartment of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands., and Jorrit-Jan Verlaan.
- Department of Orthopaedic Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands. b.j.j.bindels@umcutrecht.nl.
- Eur Spine J. 2024 May 1; 33 (5): 203120422031-2042.
PurposeTo assess whether the intention to intraoperatively reposition pedicle screws differs when spine surgeons evaluate the same screws with 2D imaging or 3D imaging.MethodsIn this online survey study, 21 spine surgeons evaluated eight pedicle screws from patients who had undergone posterior spinal fixation. In a simulated intraoperative setting, surgeons had to decide if they would reposition a marked pedicle screw based on its position in the provided radiologic imaging. The eight assessed pedicle screws varied in radiologic position, including two screws positioned within the pedicle, two breaching the pedicle cortex < 2 mm, two breaching the pedicle cortex 2-4 mm, and two positioned completely outside the pedicle. Surgeons assessed each pedicle screw twice without knowing and in random order: once with a scrollable three-dimensional (3D) image and once with two oblique fluoroscopic two-dimensional (2D) images.ResultsAlmost all surgeons (19/21) intended to reposition more pedicle screws based on 3D imaging than on 2D imaging, with a mean number of pedicle screws to be repositioned of, respectively, 4.1 (± 1.3) and 2.0 (± 1.3; p < 0.001). Surgeons intended to reposition two screws placed completely outside the pedicle, one breaching 2-4mm, and one breaching < 2 mm more often based on 3D imaging.ConclusionWhen provided with 3D imaging, spine surgeons not only intend to intraoperatively reposition pedicle screws at risk of causing postoperative complications more often but also screws with acceptable positions. This study highlights the potential of intraoperative 3D imaging as well as the need for consensus on how to act on intraoperative 3D information.© 2024. The Author(s).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.