• Interact Cardiovasc Thorac Surg · Feb 2013

    Clinical and echocardiographic outcomes after implantation of the Trifecta aortic bioprosthesis: an initial single-centre experience.

    • Angelo M Dell'Aquila, Dominik Schlarb, Stefan R B Schneider, Jürgen R Sindermann, Andreas Hoffmeier, Gerrit Kaleschke, Sven Martens, and Andreas Rukosujew.
    • Department of Cardiac Surgery, Universitätsklinikum Münster, Münster, Germany.
    • Interact Cardiovasc Thorac Surg. 2013 Feb 1;16(2):112-5.

    ObjectivesThe Trifecta valve (St. Jude Medical) was introduced into clinical practice as a tri-leaflet stented pericardial valve designed for supra-annular placement in the aortic position. The present study aims to evaluate the preliminary results with this new bioprosthesis.MethodsSeventy patients underwent aortic valve replacement (AVR) with the Trifecta valve between August 2010 and December 2011. Thirty-three patients were male and 37 were female (52.9%). Mean age was 74.65 ± 7.63 (range 47-90 years). Prevalent cause of AVR was aortic stenosis in 64 (91.43%) patients. The mean preoperative pressure gradient was 50 ± 17 (range 20-84 mmHg), and the mean aortic valve area was 0.77 ± 0.33. Five (7.14%) patients were operated on due to aortic valve endocarditis. One patient was operated on due to isolated, severe aortic insufficiency. All patients were in New York Heart Association functional class III or IV. Twenty-eight (40%) patients underwent concomitant procedures.ResultsConcomitant procedures were coronary artery bypass grafting (n = 25), mitral valve replacement (n = 1), ablation of atrial fibrillation (n = 1) and septal myomectomy (n = 1). There were no intraoperative deaths. The 30-day in-hospital mortality was 2.85% (2 of 70). One late death occurred during the in-hospital stay due to a multiorgan failure on postoperative day 60. There were 2 (2.85%) perioperative strokes. Mean pressure gradient decreased significantly from a preoperative value of 50 ± 17 mmHg to an intraoperative gradient of 9 ± 4 mmHg (Table 3). The mean gradients were 14, 11, 11, 8 and 6 mmHg for the 19, 21, 23, 25 and 27 mm valve size, respectively. No prosthesis dislocation, endocarditis, valve thrombosis or relevant aortic regurgitation was observed at discharge.ConclusionsThe initial experience with the Trifecta valve bioprosthesis shows excellent outcomes with favourable early haemodynamics. Further studies with longer follow-up are needed to confirm those preliminary results.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.