• Anesthesiology · May 2024

    Modified Thermodilution for Simultaneous Cardiac Output and Recirculation Assessment in Veno-venous Extracorporeal Membrane Oxygenation: A Prospective Diagnostic Accuracy Study.

    • David Berger, Elia J Stanger, Hansjörg Jenni, Philipp D Fried, and Kaspar F Bachmann.
    • Department of Intensive Care Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
    • Anesthesiology. 2024 May 1; 140 (5): 100210151002-1015.

    BackgroundThermodilution is unreliable in veno-venous extracorporeal membrane oxygenation (VV-ECMO). Systemic oxygenation depends on recirculation fractions and ratios of extracorporeal membrane oxygenation (ECMO) flow to cardiac output. In a prospective in vitro simulation, this study assessed the diagnostic accuracy of a modified thermodilution technique for recirculation and cardiac output. The hypothesis was that this method provided clinically acceptable precision and accuracy for cardiac output and recirculation.MethodsTwo ECMO circuits ran in parallel: one representing a VV-ECMO and the second representing native heart, lung, and circulation. Both circuits shared the right atrium. Extra limbs for recirculation and pulmonary shunt were added. This study simulated ECMO flows from 1 to 2.5 l/min and cardiac outputs from 2.5 to 3.5 l/min with recirculation fractions (0 to 80%) and pulmonary shunts. Thermistors in both ECMO limbs and the pulmonary artery measured the temperature changes induced by cold bolus injections into the arterial ECMO limb. Recirculation fractions were calculated from the ratio of the areas under the temperature curve (AUCs) in the ECMO limbs and from partitioning of the bolus volume (flow based). With known partitioning of bolus volumes between ECMO and pulmonary artery, cardiac output was calculated. High-precision ultrasonic flow probes served as reference for Bland-Altman plots and linear mixed-effect models.ResultsAccuracy and precision for both the recirculation fraction based on AUC (bias, -5.4%; limits of agreement, -18.6 to 7.9%) and flow based (bias, -5.9%; limits of agreement, -18.8 to 7.0%) are clinically acceptable. Calculated cardiac output for all recirculation fractions was accurate but imprecise (RecirculationAUC: bias 0.56 l/min; limits of agreement, -2.27 to 3.4 l/min; and RecirculationFLOW: bias 0.48 l/min; limits of agreement, -2.22 to 3.19 l/min). Recirculation fraction increased bias and decreased precision.ConclusionsAdapted thermodilution for VV-ECMO allows simultaneous measurement of recirculation fraction and cardiac output and may help optimize patient management with severe respiratory failure.Copyright © 2023 The Author(s). Published by Wolters Kluwer Health, Inc., on behalf of the American Society of Anesthesiologists.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…