• Ann Emerg Med · Aug 2024

    Right Ventricular "Bubble Time" to Identify Patients With Right Ventricular Dysfunction.

    • Allison Cohen, Timmy Li, Nicholas Bielawa, Alexander Nello, Allen Gold, Margaret Gorlin, Mathew Nelson, Edward Carlin, and Daniel Rolston.
    • Department of Emergency Medicine, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY; Department of Emergency Medicine, North Shore University Hospital, Manhasset, NY. Electronic address: acohen20@northwell.edu.
    • Ann Emerg Med. 2024 Aug 1; 84 (2): 182194182-194.

    Study ObjectiveWe propose a novel method of evaluating right ventricular (RV) dysfunction in the emergency department (ED) using RV "bubble time"-the duration of time bubbles from a saline solution flush are visualized in the RV on echocardiography. The objective was to identify the optimal cutoff value for RV bubble time that differentiates patients with RV dysfunction and report on its diagnostic test characteristics.MethodsThis prospective diagnostic accuracy study enrolled a convenience sample of hemodynamically stable patients in the ED. A sonographer administered a 10-mL saline solution flush into the patient's intravenous catheter, performed a bedside echocardiogram, and measured RV bubble time. Subsequently, the patient underwent a comprehensive cardiologist-interpreted echocardiogram within 36 hours, which served as the gold standard. Patients with RV strain or enlargement of the latter found on an echocardiogram were considered to have RV dysfunction. Bubble time was evaluated by a second provider, blinded to the initial results, who reviewed the ultrasound clips. The primary outcome measure was the optimal cutoff value of RV bubble time that identifies patients with and without RV dysfunction.ResultsOf 196 patients, median age was 67 year, and half were women, with 69 (35.2%) having RV dysfunction. Median RV bubble time among patients with RV dysfunction was 62 seconds (interquartile range [IQR]: 52, 93) compared with 21 seconds (IQR: 12, 32) among patients without (P<.0001). The optimal cutoff value of RV bubble time for identifying patients with RV dysfunction was 40 or more seconds, with a sensitivity of 0.97 (95% CI 0.93 to 1.00) and specificity of 0.87 (95% CI 0.82 to 0.93).ConclusionIn patients in the ED, an RV bubble time of 40 or more seconds had high sensitivity in identifying patients with RV dysfunction, whereas an RV bubble time of less than 40 seconds had good specificity in identifying patients without RV dysfunction. These findings warrant further investigation in undifferentiated patient populations and by emergency physicians without advanced ultrasound training.Copyright © 2024 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…