- Harold Mulier, StruysMichel M R FMMRF0000-0003-0421-536XDepartment of Anaesthesiology, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands.Department of Basic and Applied Medical Sciences, Ghent University, Gent, Belgium., Hugo Vereecke, Steffen Rex, An Teunkens, and Alain F Kalmar.
- Department of Anaesthesiology, University Hospitals Leuven, Leuven, Belgium.
- Anaesthesia. 2024 Aug 1; 79 (8): 849855849-855.
BackgroundRecommendations exist that aim to mitigate the substantial ecological impact of anaesthesia. One option is to use anaesthetic gas capturing technology at anaesthesia workstation exhausts to harvest and recycle volatile agents. However, the efficiency of such technology is mainly unverified in vivo.MethodsThe efficiency of CONTRAfluran™ in capturing sevoflurane from an anaesthesia workstation exhaust (when set to minimal flow and end-tidal control mode) was evaluated in 70 adult patients scheduled for general or bariatric laparoscopic surgery. The weight of the sevoflurane vaporiser and CONTRAfluran canister was measured before and after each case, to calculate total sevoflurane consumption and retention. Retention was measured after the minimal flow maintenance phase and after the high flow washout phase. The total retention efficiency was the fraction of all consumed sevoflurane captured by the CONTRAfluran canister. The primary objective was to examine the retention efficiency of CONTRAfluran in a clinical surgical setting, where all feasible strategies to minimise sevoflurane consumption and optimise the efficacy of CONTRAfluran were utilised. The secondary objective was to analyse the correlation between mass transfer and the duration of the case.ResultsMean (SD) volume of sevoflurane captured using CONTRAfluran was 4.82 (1.41) ml, representing 45% (95%CI 42-48%) of all sevoflurane administered. The highest amount of retention was found during the washout phase. Retention efficiency did not correlate with the duration of the case.ConclusionsOver half of the sevoflurane administered was not captured by the CONTRAfluran canister when minimal flow techniques were used, likely due to residual accumulation of sevoflurane in the patient after tracheal extubation or, to a lesser extent, due to ventilation system leakage. However, as every prevented emission is commendable, CONTRAfluran may be a potentially valuable tool for reducing the environmental footprint of sevoflurane-based anaesthesia.© 2024 Association of Anaesthetists.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.