Minerva anestesiologica · Jul 2008
Comparative Study Clinical TrialThe ability of PiCCO versus LiDCO variables to detect changes in cardiac index: a prospective clinical study.
- A Donati, R Nardella, V Gabbanelli, M Scarcella, M Romanelli, L Romagnoli, L Botticelli, S Pantanetti, and P Pelaia.
- Anesthesia and Intensive Care Unit, Department of Neurosciences, Polytechnic University of Marche, Ancona, Italy. donati.abele@tiscali.it
- Minerva Anestesiol. 2008 Jul 1;74(7-8):367-74.
BackgroundBoth PiCCO and LiDCO can provide dynamic preload parameters, pulse pressure variation (PPV) and stroke volume variation (SVV). The PiCCO device also provides a measure of intrathoracic blood volume index (ITBVI). We investigated the agreement between SVV and PPV, as well as the reliability of LiDCO- and PiCCO-measured SVV, PPV and ITBVI, in detecting fluid responsiveness before and after fluid challenge (FC).MethodsWe performed a prospective clinical study in University Hospital ICU. Nine adult ICU patients with cardiovascular instability were enrolled in the study. All patients were sedated and mechanically ventilated with intermittent positive pressure ventilation. The PiCCO and LiDCO systems were both connected to each patient. The PiCCO pulse waveform system was joined by a 5-French (Fr) thermistor-tipped arterial catheter inserted into the femoral artery. LiDCO measurements were performed through radial artery pulse contour analysis. Fluid challenge was performed using a rapid infusion of 7 mL/kg of 6% hydroxyethylstarch over 30 min.ResultsMeasurements of CI, ITBVI, SVV, and PVV were made using both techniques before and after FC. Pre-FC cardiac index (CI) measurements were similar with both devices, although the reading was higher after FC with the PiCCO device (P<0.001). The correlation coefficient between PiCCO-CI and LiDCO-CI was 0.85 (95% CI: 0.69 to 0.93; P<0.001); for P-PPV and L-PPV, it was 0.74 (95% CI: 0.49 to 0.88; P<0.001). Only ITBV had a significant correlation with LiDCO-CI or PiCCO-CI.ConclusionWe found a narrow bias but less accurate precision in cardiac index values measured by a radial artery-site LiDCO catheter and a femoral artery-site PiCCO catheter, with poor agreement between radial and femoral-derived SVV and PPV measurements. ITBVI proved to be the best predictor of fluid responsiveness. The SVV does not seem to be reliable for preload optimization in ICU patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.