- M Bijak, W Mayr, W Girsch, H Lanmüller, E Unger, H Stöhr, H Thoma, and H Plenk.
- Department of Biomedical Engineering and Physics, University of Vienna, AKH 4/L, Waeringer Guertel 18-20, A-1090 Vienna, Austria. m.bijak@bmtp.akh-wien.ac.at
- Artif Organs. 2001 Jun 1;25(6):467-74.
AbstractA newly developed implantable stimulator with 20 output channels, mainly intended for the stimulation of lower extremities in paraplegics, was implanted in 6 sheep over a time period of 26 weeks. Five epineural electrodes each were used to contact various nerves at different locations to elicit hip and knee extension and flexion and to make carrousel and selective stimulation possible. Different electrode application strategies in view of paraplegic standing and walking were investigated. Additional implanted electrodes allowed M-wave monitoring for selectivity investigations in 3 sheep. Stimulator, electrode leads, and electrodes proved to be reliable. Selective stimulation with electrodes placed on the trunk of the sciatic nerve could be demonstrated but with bad reproducibility. Histological investigation of the tissues surrounding electrodes and leads showed the expected stable foreign body response. Strong hip and knee extension could be gained in all cases while only weak flexion forces could be elicited in most cases. Muscle biopsies showed that daily stimulation for 8 h at threshold level caused an increase in muscle Type I fibers and a decrease in Type IIc fibers. Implants and electrodes fulfill the most important functional and biological criteria for their clinical application for paraplegic walking. The intention to provide selective flexion functions via epineural stimulation could not be demonstrated sufficiently in this animal model.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.