• Chest · Dec 1994

    Diagnostic accuracy and therapeutic impact of transthoracic and transesophageal echocardiography in mechanically ventilated patients in the ICU.

    • P Vignon, H Mentec, S Terré, H Gastinne, P Guéret, and F Lemaire.
    • Department of Intensive Care, Dupuytren hospital, Limoges, France.
    • Chest. 1994 Dec 1;106(6):1829-34.

    Study ObjectivesTo assess the respective diagnostic accuracy of transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) and their therapeutic implications in mechanically ventilated patients, in the intensive care unit (ICU).DesignA prospective study.SettingsIntensive care units of two tertiary referral teaching hospitals.PatientsOne hundred eleven ICU patients (81 men and 30 women; mean age 57 +/- 16 years). Fifty-seven percent were hospitalized for medical illnesses, 16.5 percent after thoracic surgery, 10.5 percent after other surgery, and 16.0 percent for multiple trauma. Their Simplified Acute Physiologic Score was 16 +/- 5.InterventionsThe echocardiograms were performed in order to solve well-defined clinical problems. TTE was the first step of the procedure and TEE was performed only when (1) TTE did not solve the clinical problems, and (2) TTE yielded unsuspected findings requiring TEE. During each echocardiographic study, the following were noted: ventilatory mode, clinical problems, imaging quality, results, consequence on acute care, duration of the procedure, and potential complications of TEE. Diagnostic accuracy was defined as the proportion of solved problems, and therapeutic impact was defined as changes on acute care that resulted directly from the procedure.Measurements And ResultsOne hundred twenty-eight consecutive TTE and 96 TEE were performed. TTE solved 60 of 158 clinical problems (38 percent), whether positive end-expiratory pressure (> 4 cm H2O) was present or not (28 of 74 vs 32 of 84: p > 0.50). TTE allowed evaluation of left ventricular function in 77 percent of cases and pericardial effusion in every case, but it did not solve most of the other clinical problems. Indeed, the diagnostic accuracy of TEE was markedly superior (95/98 vs 60/158: p < 0.001), but TEE required a physician's presence longer (43 +/- 17 min vs 27 +/- 12 min: p < 0.001). When TTE and TEE were scheduled (n = 96), TEE yielded an additional diagnosis or excluded with more certitude a suspected diagnosis, except in two cases. TEE had a therapeutic impact more frequently than TTE (35/96 vs 20/128: p < 0.001). Cardiovascular surgery was prompted by echocardiographic findings in ten patients. TEE was well tolerated in all patients; there were no complications.ConclusionsTEE is a valuable well-tolerated imaging technique in mechanically ventilated patients. For the assessment of left ventricular systolic function and pericardial effusion; however, TTE continues to be an excellent diagnostic tool, even when positive end-expiratory pressure is present. Both TTE and TEE have a therapeutic impact in approximately 25 percent of cases.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.