    Load shift of the intervertebral disc after a vertebroplasty: a finite-element study.

    • G Baroud, J Nemes, P Heini, and T Steffen.
    • Orthopaedic Research Laboratory, Division of Orthopaedic Surgery, McGill University, Royal Victoria Hospital, Rm L4.65, 687 Pine Avenue West, H3A 1A1, Montreal, Quebec, Canada. gbaroud@orl.mcgill.ca
    • Eur Spine J. 2003 Aug 1; 12 (4): 421426421-6.

    AbstractInfiltrating osteoporotic cancellous bone with bone cement (vertebroplasty) is a novel surgical procedure to stabilize and prevent osteoporotic vertebral fractures. Short-term clinical and biomechanical results are encouraging; however, so far no reports on long-term results have been published. Our clinical observations suggest that vertebroplasty may induce subsequent fractures in the vertebrae adjacent to the ones augmented. At this point, there is only a limited understanding of what causes these fractures. We have previously hypothesized that adjacent fractures may result from a shift in stiffness and load following rigid augmentation. The purpose of this study is to determine the load shift in a lumbar motion segment following vertebroplasty. A finite-element (FE) model of a lumbar motion segment (L4-L5) was used to quantify and compare the pre- and post-augmentation stiffness and loading (load shift) of the intervertebral (IV) disc adjacent to the augmented vertebra in response to quasi-static compression. The results showed that the rigid cement augmentation underneath the endplates acted as an upright pillar that severely reduced the inward bulge of the endplates of the augmented vertebra. The bulge of the augmented endplate was reduced to 7% of its value before the augmentation, resulting in a stiffening of the IV joint by approximately 17%, and of the whole motion segment by approximately 11%. The IV pressure accordingly increased by approximately 19%, and the inward bulge of the endplate adjacent to the one augmented (L4 inferior) increased considerably, by approximately 17%. This increase of up to 17% in the inward bulge of the endplate adjacent to the one augmented may be the cause of the adjacent fractures.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…