Cochrane Db Syst Rev · May 2024
Review Meta AnalysisContinuous infusion versus bolus injection of loop diuretics for acute heart failure.
- Debar Rasoul, Juqian Zhang, Ebony Farnell, Andreas A Tsangarides, Shiau Chin Chong, Ranga Fernando, Can Zhou, Mahnoor Ihsan, Sarah Ahmed, Tin S Lwin, Joanne Bateman, Ruaraidh A Hill, Gregory Yh Lip, and Rajiv Sankaranarayanan.
- Liverpool Centre for Cardiovascular Science, University of Liverpool, Liverpool, UK.
- Cochrane Db Syst Rev. 2024 May 22; 5 (5): CD014811CD014811.
BackgroundAcute heart failure (AHF) is new onset of, or a sudden worsening of, chronic heart failure characterised by congestion in about 95% of cases or end-organ hypoperfusion in 5% of cases. Treatment often requires urgent escalation of diuretic therapy, mainly through hospitalisation. This Cochrane review evaluated the efficacy of intravenous loop diuretics strategies in treating AHF in individuals with New York Heart Association (NYHA) classification III or IV and fluid overload.ObjectivesTo assess the effects of intravenous continuous infusion versus bolus injection of loop diuretics for the initial treatment of acute heart failure in adults.Search MethodsWe identified trials through systematic searches of bibliographic databases and in clinical trials registers including CENTRAL, MEDLINE, Embase, CPCI-S on the Web of Science, ClinicalTrials.gov, the World Health Organization (WHO) International Clinical Trials Registry platform (ICTRP), and the European Union Trials register. We conducted reference checking and citation searching, and contacted study authors to identify additional studies. The latest search was performed on 29 February 2024.Selection CriteriaWe included randomised controlled trials (RCTs) involving adults with AHF, NYHA classification III or IV, regardless of aetiology or ejection fraction, where trials compared intravenous continuous infusion of loop diuretics with intermittent bolus injection in AHF. We excluded trials with chronic stable heart failure, cardiogenic shock, renal artery stenosis, or end-stage renal disease. Additionally, we excluded studies combining loop diuretics with hypertonic saline, inotropes, vasoactive medications, or renal replacement therapy and trials where diuretic dosing was protocol-driven to achieve a target urine output, due to confounding factors.Data Collection And AnalysisTwo review authors independently screened papers for inclusion and reviewed full-texts. Outcomes included weight loss, all-cause mortality, length of hospital stay, readmission following discharge, and occurrence of acute kidney injury. We performed risk of bias assessment and meta-analysis where data permitted and assessed certainty of the evidence.Main ResultsThe review included seven RCTs, spanning 32 hospitals in seven countries in North America, Europe, and Asia. Data collection ranged from eight months to six years. Following exclusion of participants in subgroups with confounding treatments and different clinical settings, 681 participants were eligible for review. These additional study characteristics, coupled with our strict inclusion and exclusion criteria, improve the applicability of the body of the evidence as they reflect real-world clinical practice. Meta-analysis was feasible for net weight loss, all-cause mortality, length of hospital stay, readmission, and acute kidney injury. Literature review and narrative analysis explored daily fluid balance; cardiovascular mortality; B-type natriuretic peptide (BNP) change; N-terminal-proBNP change; and adverse incidents such as ototoxicity, hypotension, and electrolyte imbalances. Risk of bias assessment revealed two studies with low overall risk, four with some concerns, and one with high risk. All sensitivity analyses excluded trials at high risk of bias. Only narrative analysis was conducted for 'daily fluid balance' due to diverse data presentation methods across two studies (169 participants, the evidence was very uncertain about the effect). Results of narrative analysis varied. For instance, one study reported higher daily fluid balance within the first 24 hours in the continuous infusion group compared to the bolus injection group, whereas there was no difference in fluid balance beyond this time point. Continuous intravenous infusion of loop diuretics may result in mean net weight loss of 0.86 kg more than bolus injection of loop diuretics, but the evidence is very uncertain (mean difference (MD) 0.86 kg, 95% confidence interval (CI) 0.44 to 1.28; 5 trials, 497 participants; P < 0.001, I2 = 21%; very low-certainty evidence). Importantly, sensitivity analysis excluding trials with high risk of bias showed there was insufficient evidence for a difference in bodyweight loss between groups (MD 0.70 kg, 95% CI -0.06 to 1.46; 3 trials, 378 participants; P = 0.07, I2 = 0%). There may be little to no difference in all-cause mortality between continuous infusion and bolus injection (risk ratio (RR) 1.53, 95% CI 0.81 to 2.90; 5 trials, 530 participants; P = 0.19, I2 = 4%; low-certainty evidence). Despite sensitivity analysis, the direction of the evidence remained unchanged. No trials measured cardiovascular mortality. There may be little to no difference in the length of hospital stay between continuous infusion and bolus injection of loop diuretics, but the evidence is very uncertain (MD -1.10 days, 95% CI -4.84 to 2.64; 4 trials, 211 participants; P = 0.57, I2 = 88%; very low-certainty evidence). Sensitivity analysis improved heterogeneity; however, the direction of the evidence remained unchanged. There may be little to no difference in the readmission to hospital between continuous infusion and bolus injection of loop diuretics (RR 0.85, 95% CI 0.63 to 1.16; 3 trials, 400 participants; P = 0.31, I2 = 0%; low-certainty evidence). Sensitivity analysis continued to show insufficient evidence for a difference in the readmission to hospital between groups. There may be little to no difference in the occurrence of acute kidney injury as an adverse event between continuous infusion and bolus injection of intravenous loop diuretics (RR 1.02, 95% CI 0.70 to 1.49; 3 trials, 491 participants; P = 0.92, I2 = 0%; low-certainty evidence). Sensitivity analysis continued to show that continuous infusion may make little to no difference on the occurrence of acute kidney injury as an adverse events compared to the bolus injection of intravenous loop diuretics. Analysis of available data comparing two delivery methods of diuretics in acute heart failure found that the current data are insufficient to show superiority of one strategy intervention over the other. Our findings were based on trials meeting stringent inclusion and exclusion criteria to ensure validity. Despite previous reviews suggesting advantages of continuous infusion over bolus injections, our review found insufficient evidence to support or refute this. However, our review, which excluded trials with clinical confounders and RCTs with high risk of bias, offers the most robust conclusion to date.Copyright © 2024 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.