• Cochrane Db Syst Rev · May 2024

    Review Meta Analysis

    Noise or sound management in the neonatal intensive care unit for preterm or very low birth weight infants.

    • Greta Sibrecht, Katarzyna Wróblewska-Seniuk, and Matteo Bruschettini.
    • II Department of Neonatology, Poznan University of Medical Sciences, Poznan, Poland.
    • Cochrane Db Syst Rev. 2024 May 30; 5 (5): CD010333CD010333.

    BackgroundInfants in the neonatal intensive care unit (NICU) are subjected to different types of stress, including sounds of high intensity. The sound levels in NICUs often exceed the maximum acceptable level recommended by the American Academy of Pediatrics, which is 45 decibels (dB). Hearing impairment is diagnosed in 2% to 10% of preterm infants compared to only 0.1% of the general paediatric population. Bringing sound levels under 45 dB can be achieved by lowering the sound levels in an entire unit; by treating the infant in a section of a NICU, in a 'private' room, or in incubators in which the sound levels are controlled; or by reducing sound levels at the individual level using earmuffs or earplugs. By lowering sound levels, the resulting stress can be diminished, thereby promoting growth and reducing adverse neonatal outcomes. This review is an update of one originally published in 2015 and first updated in 2020.ObjectivesTo determine the benefits and harms of sound reduction on the growth and long-term neurodevelopmental outcomes of neonates.Search MethodsWe used standard, extensive Cochrane search methods. On 21 and 22 August 2023, a Cochrane Information Specialist searched CENTRAL, PubMed, Embase, two other databases, two trials registers, and grey literature via Google Scholar and conference abstracts from Pediatric Academic Societies.Selection CriteriaWe included randomised controlled trials (RCTs) or quasi-RCTs in preterm infants (less than 32 weeks' postmenstrual age (PMA) or less than 1500 g birth weight) cared for in the resuscitation area, during transport, or once admitted to a NICU or stepdown unit. We specified three types of intervention: 1) intervention at the unit level (i.e. the entire neonatal department), 2) at the section or room level, or 3) at the individual level (e.g. hearing protection).Data Collection And AnalysisWe used the standardised review methods of Cochrane Neonatal to assess the risk of bias in the studies. We used the risk ratio (RR) and risk difference (RD), with their 95% confidence intervals (CIs), for dichotomous data. We used the mean difference (MD) for continuous data. Our primary outcome was major neurodevelopmental disability. We used GRADE to assess the certainty of the evidence.Main ResultsWe included one RCT, which enroled 34 newborn infants randomised to the use of silicone earplugs versus no earplugs for hearing protection. It was a single-centre study conducted at the University of Texas Medical School in Houston, Texas, USA. Earplugs were positioned at the time of randomisation and worn continuously until the infants were 35 weeks' postmenstrual age (PMA) or discharged (whichever came first). Newborns in the control group received standard care. The evidence is very uncertain about the effects of silicone earplugs on the following outcomes. • Cerebral palsy (RR 3.00, 95% CI 0.15 to 61.74)and Mental Developmental Index (MDI) (Bayley II) at 18 to 22 months' corrected age (MD 14.00, 95% CI 3.13 to 24.87); no other indicators of major neurodevelopmental disability were reported. • Normal auditory functioning at discharge (RR 1.65, 95% CI 0.93 to 2.94) • All-cause mortality during hospital stay (RR 2.07, 95% CI 0.64 to 6.70; RD 0.20, 95% CI -0.09 to 0.50) • Weight (kg) at 18 to 22 months' corrected age (MD 0.31, 95% CI -1.53 to 2.16) • Height (cm) at 18 to 22 months' corrected age (MD 2.70, 95% CI -3.13 to 8.53) • Days of assisted ventilation (MD -1.44, 95% CI -23.29 to 20.41) • Days of initial hospitalisation (MD 1.36, 95% CI -31.03 to 33.75) For all outcomes, we judged the certainty of evidence as very low. We identified one ongoing RCT that will compare the effects of reduced noise levels and cycled light on visual and neural development in preterm infants.Authors' ConclusionsNo studies evaluated interventions to reduce sound levels below 45 dB across the whole neonatal unit or in a room within it. We found only one study that evaluated the benefits of sound reduction in the neonatal intensive care unit for hearing protection in preterm infants. The study compared the use of silicone earplugs versus no earplugs in newborns of very low birth weight (less than 1500 g). Considering the very small sample size, imprecise results, and high risk of attrition bias, the evidence based on this research is very uncertain and no conclusions can be drawn. As there is a lack of evidence to inform healthcare or policy decisions, large, well designed, well conducted, and fully reported RCTs that analyse different aspects of noise reduction in NICUs are needed. They should report both short- and long-term outcomes.Copyright © 2024 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…