-
Multicenter Study
Temporal Shape Changes of Pedicle screw-rod Constructs After Lumbar Interbody Fusion.
- Munenari Ikezawa, Satoru Tanioka, Hirofumi Nishikawa, Orhun Utku Aydin, Adam Hilbert, Takahiro Miyazaki, Masashi Fujimoto, Fujimaro Ishida, Yusuke Kamei, Hidenori Suzuki, Masaki Mizuno, and Dietmar Frey.
- Department of Neurosurgery, Mie Chuo Medical Center, Tsu, Mie, Japan.
- Spine. 2024 Nov 1; 49 (21): 150415111504-1511.
Study DesignRetrospective multicenter study.ObjectiveTo examine the shape change of screw-rod constructs over time after short-segment lumbar interbody fusion and to clarify its relationship to clinical characteristics.Summary Of Background DataNo study has focused on the shape change of screw-rod constructs after short-segment fusion and its clinical implications.MethodsOne hundred eight patients who had single-level lumbar interbody fusion with pedicle screws and cages were enrolled. Three-dimensional (3D) images of screw-rod constructs were generated from baseline CT on the day after surgery and follow-up CT and were superposed on the right and left side, respectively, using the iterative closest point algorithm. The shape change was quantitatively assessed by computing the median distance between the 3D images, which was defined as the shape change value. Among the 5 time-course categories of follow-up CT (≤1, 2-3, 4-6, 7-12, and ≥13 months), the shape change values were compared. The relationships between the shape change values and clinical characteristics, such as age, CT-derived vertebral bone mineral density, screw and rod materials, and postoperative interbody fusion status, cage subsidence, and screw loosening, were evaluated.ResultsA total of 237 follow-up CTs were included (≤1 [34 scans], 2-3 [33 scans], 4-6 [80 scans], 7-12 [48 scans], and ≥13 months [42 scans]) because many patients underwent multiple follow-up CTs. There were significant differences in shape change values among the time-course categories ( P <0.001 in Kruskal-Wallis test). Most shape changes occurred within 6 months postoperatively, with no significant changes observed at 7 months or more. There were no significant relationships between the shape change values and each clinical characteristic.ConclusionsThe temporal shape changes of screw-rod constructs following short-segment lumbar interbody fusion progressed up to 6 months after surgery but not significantly thereafter.Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.