- Ali Aktaş, Hakan Özer, İsmail Baloğlu, Halil Zeki Tonbul, İbrahim Güney, and Nedim Yılmaz Selçuk.
- Department of Internal Medicine, Faculty of Meram Medicine, Necmettin Erbakan University, Konya, Turkiye.
- Turk J Med Sci. 2023 Jan 1; 53 (6): 186318691863-1869.
Background And AimThere are over 60,000 hemodialysis (HD) patients in Türkiye, and the number of patients is increasing yearly. Dialysate flow rate (Qd) is a factor in HD adequacy. Approximately 150 L of water are consumed per session to prepare the dialysate. We aimed to investigate whether HD effectiveness can be achieved at a low Qd in different patient groups for the purpose of saving water.Materials And MethodsThis prospective study included 81 HD patients from 2 centers. The patients underwent an aggregate total of 486 HD sessions, including 3 sessions at a Qd of 500 mL/min and 3 sessions at a Qd of 300 mL/min for each patient. We used online Kt/V readings recorded at the end of each dialysis session to compare the effectiveness of these 2 types of HD session performed at a different Qd.ResultsThe online Kt/V readings were similar between the standard (500) and low (300) Qd HD (1.51 ± 0.41 and 1.49 ± 0.44, respectively, p = 0.069). In the subgroup analyses, men had higher online Kt/V values at the standard Qd compared to the low Qd (1.35 ± 0.30 and 1.30 ± 0.32, respectively, p = 0.019), but the Kt/V values were not different for women. While the low Qd did not reduce online Kt/V in patients using small surface area dialysis membranes (1.75 ± 0.35 for 300 Qd and 1.75 ± 0.32 for 500 Qd, p = 0.931), it was associated with reduced online Kt/V in patients using large surface area dialysis membranes (1.12 ± 0.25 for 300 Qd and 1.17 ± 0.24 for 500 Qd, p = 0.006). The low Qd did not result in differences in online Kt/V among low-weight patients. However, online Kt/V values were better with the standard Qd in patients weighing 65 kg and above.ConclusionIn our study, dialysis adequacy at a reduced dialysate flow was not inferior for women, patients with low body weight, or patients using small surface area membranes. Individualized HD at a reduced Qd of 300 mL/min in eligible patients can save 48 L of water per HD session and an average of 7500 L of water per year.© TÜBİTAK.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.