-
Ulus Travma Acil Cerrahi Derg · Jun 2024
Comparative StudyComparison of the Kron technique and digital manometry for measuring intra-abdominal pressure in emergency department patients diagnosed with ileus.
- Merve Unutmaz, Çağdaş Yıldırım, Mehmet Emin Unutmaz, Pamukçu GünaydınGülGDepartment of Emergency Medicine, Ankara Yıldırım Beyazıt University, School of Medicine, Ankara-Türkiye., Alp Şener, and Şervan Gökhan.
- Department of Emergency Medicine, Ankara Bilkent City Hospital, Ankara-Türkiye.
- Ulus Travma Acil Cerrahi Derg. 2024 Jun 1; 30 (6): 437443437-443.
BackgroundNumerous measurement techniques for intra-abdominal pressure have been explored, with the Kron Technique established as the gold standard. Despite its prominence, the search for alternative methods persists due to its lengthy application time, the requirement for additional equipment, and overall impracticality. This study investigated a quicker, more accessible method for effective intra-abdominal pressure measurement in the emergency department. It aimed to compare intra-abdominal pressure measurements in patients diagnosed with ileus using a digital manometer and the Kron Technique.MethodsConducted from October 2022 to February 2023, this single-center, prospective, single-blind method comparison study involved patients diagnosed with ileus at a tertiary emergency department. Intra-abdominal pressure was measured using both the Kron Technique and a digital manometer by separate practitioners blinded to the study results.ResultsThe study included 30 patients. No statistically significant difference was observed in the intra-abdominal pressure measurements between the two methods (p<0.237). A very strong correlation existed between the two methods (Spearman's Rho = 0.998). Bland-Altman analysis showed a bias value of 0.091 mmHg for the digital manometer, with upper and lower agreement limits of -0.825 and 1.007 mmHg, respectively. The measurement time was significantly shorter with the digital manometer than with the Kron Technique (15 vs. 390.5 seconds; p<0.001).ConclusionWe believe that the intra-abdominal pressure measurement technique using a digital manometer is a method that can be effectively employed by healthcare professionals in emergency departments. This technique offers ease of use, requires minimal equipment, provides rapid results, and delivers reliable measurement values compared to the Kron Technique.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.