• Br J Anaesth · Dec 2024

    Efficiency of passive activated carbon anaesthetic gas capturing systems during simulated ventilation.

    • Christin Wenzel, Bernd Flamm, Torsten Loop, Stefan Schumann, and Johannes Spaeth.
    • Department of Anesthesiology and Critical Care, University of Freiburg Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany. Electronic address: christin.wenzel@uniklinik-freiburg.de.
    • Br J Anaesth. 2024 Dec 1; 133 (6): 151815241518-1524.

    BackgroundInterest in passive flow filter systems to remove sevoflurane from anaesthetic machine exhaust have increased recently to mitigate the environmental impact of volatile anaesthetics. These filter systems consist of chemically activated carbon, with limited evidence on their performance characteristics. We hypothesised that their efficiency depends on filter material.MethodsBinding capacity was tested for three carbon filter materials (CONTRAfluran®, FlurAbsorb®, and Anaesthetic Agent Filter AAF633). Adsorption efficiency and resistive pressure were determined during simulated ventilation at different stages of filter saturation and fresh gas flow. In addition, sevoflurane concentration in filtered gas was measured at randomly selected anaesthesia workstations.ResultsSevoflurane concentration in filtered gas exceeded 10 ppm when saturated with 184 ml sevoflurane each for CONTRAfluran and FlurAbsorb and 276 ml for AAF633. During simulated ventilation, sevoflurane concentration >10 ppm passed through CONTRAfluran and AAF633 at fresh gas flow 10 L min-1 only at maximum saturation, but through FlurAbsorb at all stages of saturation. The resistance pressure of all filters was negligible during simulated ventilation, but increased up to 5.2 (0.2) cm H2O during simulated coughing. At two of seven anaesthesia workstations, sevoflurane concentration in filtered exhaust gas was >10 ppm.ConclusionsDepending on the filter material and saturation, the likelihood of sevoflurane passing through passive flow carbon filters depends on the filter material and fresh gas flow. Combining the filter systems with anaesthetic gas scavenging systems could protect from pollution of ambient air with sevoflurane.Copyright © 2024 The Authors. Published by Elsevier Ltd.. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…