• J Clin Monit Comput · Oct 2024

    Vasoconstriction with phenylephrine increases cardiac output in preload dependent patients.

    • Jakob Højlund, Mirjana Cihoric, and Nicolai Bang Foss.
    • Department of Anaesthesiology, Hvidovre University Hospital, Capital Region, Denmark. jakob.hoejlund@regionh.dk.
    • J Clin Monit Comput. 2024 Oct 1; 38 (5): 9971002997-1002.

    AbstractGeneral Anaesthesia (GA) is accompanied by a marked decrease in sympathetic outflow and thus loss of vasomotor control of cardiac preload. The use of vasoconstriction during GA has mainly focused on maintaining blood pressure. Phenylephrine (PE) is a pure α1-agonist without inotropic effects widely used to correct intraoperative hypotension. The potential of PE for augmenting cardiac stroke volume (SV) and -output (CO) by venous recruitment is controversial and no human studies have explored the effects of PE in preload dependent circulation using indicator dilution technique. We hypothesized that PE-infusion in patients with cardiac stroke volume limited by reduced preload would restore preload and thus augment SV and CO. 20 patients undergoing GA for gastrointestinal surgery were monitored with arterial catheter and LiDCO unity monitor. Upon stable haemodynamics after induction patients were placed in head-up tilt (HUT). All patients became preload responsive as verified by a stroke volume variation (SVV) of > 12%. PE-infusion was then started at 15-20mikrg/min and adjusted until preload was restored (SVV < 12%). Li-dilution cardiac output (CO) was initially measured after induction (baseline), again with HUT in the preload responsive phase, and finally when preload was restored with infusion of PE.At baseline SVV was 10 ± 3% (mean ± st.dev.), CI was 2,6 ± 0,4 L/min*m2, and SVI 43 ± 7mL/m2. With HUT SVV was 19 ± 4%, CI was 2,2 ± 0,4 L/min*m2, SVI 35 ± 7mL/m2. During PE-infusion SVV was reduced to 6 ± 3%, CI increased to 2,6 ± 0,5 L/min*m2, and SVI increased to 49 ± 11mL/m2. All differences p < 0,001. In conclusion: Infusion of phenylephrine during preload dependency increased venous return abolishing preload dependency as evaluated by SVV and increased cardiac stroke volume and -output as measured by indicator-dilution technique. (ClinicalTrials.gov NCT05193097).© 2024. The Author(s).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…