• J. Thorac. Cardiovasc. Surg. · May 2024

    Validation of the HeartMate 3 survival risk score in a large left ventricular assist device center.

    • Cathrine M Moeller, Gal Rubinstein, Daniel Oren, Andrea Fernandez Valledor, Dor Lotan, Jayant K Raikhelkar, Kevin J Clerkin, Paolo C Colombo, Nicole E Leahy, Justin A Fried, Yuji Kaku, Yoshifumi Naka, Koji Takeda, Melana Yuzefpolskaya, Veli K Topkara, Gabriel T Sayer, and Nir Uriel.
    • Division of Cardiology, Department of Medicine, Columbia University Irving Medical Center, New York, NY.
    • J. Thorac. Cardiovasc. Surg. 2024 May 28.

    ObjectiveThe HeartMate 3 survival risk score was recently validated in the Multicenter study Of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 to predict patient-specific survival in HeartMate 3 left ventricular assist device candidates. The HeartMate 3 survival risk score stratifies individuals into tertiles according to survival probability.MethodsWe performed a single-center retrospective review of all HeartMate 3 left ventricular assist device recipients between September 2017 and August 2022. Baseline characteristics were collected from the electronic medical records. HeartMate 3 survival risk scores were calculated for all eligible patients. One- and 2-year Kaplan-Meier survival analyses were conducted. A univariate and multivariable Cox regression model was used to identify predictors.ResultsA total of 181 patients were included in this final analysis. The median age was 62 years, 83% were male, and 26% were Interagency Registry for Mechanically Assisted Circulatory Support Profile 1. The mean HeartMate 3 survival risk score for the entire cohort was 2.66 ± 0.66. Two-year survivals in the high, average, and low survival groups were 93.5% ± 3.2%, 81.6% ± 7.4%, and 82.0% ± 6.6%, respectively. As a continuous variable, the unadjusted HeartMate 3 survival risk score was a significant predictor of mortality (hazard ratio, 2.20; 95% CI, 1.08-4.45; P = .029). The areas under the curve were 0.70 and 0.66 at 1 and 2 years, respectively. We were unable to demonstrate the discriminatory ability of the HeartMate 3 survival risk score using the original stratification, but we found significantly increased survival in the high survival group using a binary cutoff (hazard ratio, 4.8; 95% CI, 1.01-20.9; P = .038).ConclusionsThe unadjusted HeartMate 3 survival risk score was associated with postimplant survival in patients outside of the Multicenter study Of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 but did not remain an independent predictor after adjusting for ischemic etiology and severe diabetes. The HeartMate 3 survival risk score was able to identify patients at high survival using a binary cutoff, but we were unable to demonstrate its discriminatory ability among the previously published risk tertiles.Published by Elsevier Inc.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…