• Spine · Jul 2024

    Interspinous Motion Measurement Could Serve as a Quantitative Method for Assessing Bony Fusion after Anterior Cervical Corpectomy and Fusion (ACCF).

    • Haoxiang Wang, Tian Xia, Ruomu Qu, Yu Sun, Fengshan Zhang, Shengfa Pan, Xin Chen, Yanbin Zhao, Liang Jiang, and Feifei Zhou.
    • Peking University Third Hospital, Department of Orthopaedics.
    • Spine. 2024 Jul 23.

    Study DesignA retrospective diagnostic test study.ObjectiveTo establish quantitative fusion criteria for ACCF.Summary Of Background DataCurrently, the criteria of fusion after ACCF remains controversial. Evaluation techniques such as observation of continuous bony trabeculae across the fusion site, were qualitative and conducted by naked eyes, limiting its accuracy. Dynamic fusion indicators such as interspinous motion (ISM), have been successfully utilized in anterior cervical discectomy and fusion (ACDF) for evaluating fusion and detecting pseudarthrosis. However, the accuracy of ISM in ACCF is unclear.MethodsPatients underwent ACCF in our hospital were reviewed. Imaging data including dynamic radiographs and computed tomography (CT) scans were collected. The distance and angle form of ISM (ISM-dis and ISM-ang) were measured on dynamic radiograph, with CT as the gold standard for fusion. The correlation between ISM methods was analyzed using Spearmann correlation. Receiver Operating Characteristic (ROC) curves were used to evaluate the accuracy and generate optimal cut-off values. Three observers independently measured the data twice to determine interobserver and intraobserver reliability.ResultsOur study included 178 imaging datasets. ISM-dis showed positive correlation with ISM-ang (r=0.914). The area under ROC (AUC) for ISM-dis and ISM-ang was 0.926 and 0.893. Applying a cutoff value of 1.50 mm to ISM-dis yielded a sensitivity of 87.8% and specificity of 92.3% for detecting pseudarthrosis. For ISM-ang, a cutoff value of 1.75° resulted in a sensitivity of 79.1% and specificity of 92.3%. Intraobserver reliabilities for ISM-dis (0.986, 0.984 and 0.972) were higher than for ISM-ang (0.935, 0.963 and 0.935), as was interobserver reliability (0.985 for ISM-dis and 0.956 for ISM-ang). Fusion rates calculated using ISM-dis and ISM-ang were 52.4% and 61.9%.ConclusionISM can serve as an alternative to CT for assessing fusion, with ISM-dis at a 1.50 mm cutoff and ISM-ang at 1.75° demonstrating high diagnostic accuracy.Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…