    Ultrasonography for confirmation of gastric tube placement.

    • Yasushi Tsujimoto, Yuki Kataoka, Masahiro Banno, Keisuke Anan, Akihiro Shiroshita, and Satoshi Jujo.
    • Department of Health Promotion and Human Behavior, Kyoto University Graduate School of Medicine/School of Public Health, Kyoto, Japan.
    • Cochrane Db Syst Rev. 2024 Jul 25; 7 (7): CD012083CD012083.

    BackgroundGastric tubes are commonly used for the administration of drugs and tube feeding for people who are unable to swallow. Feeding via a tube misplaced in the trachea can result in severe pneumonia. Therefore, the confirmation of tube placement in the stomach after tube insertion is important. Recent studies have reported that ultrasonography provides good diagnostic accuracy estimates in the confirmation of appropriate tube placement. Hence, ultrasound could provide a promising alternative to X-rays in the confirmation of tube placement, especially in settings where X-ray facilities are unavailable or difficult to access.ObjectivesTo assess the diagnostic accuracy of ultrasound alone or in combination with other methods for gastric tube placement confirmation in children and adults.Search MethodsThis systematic review is an update of a previously published Cochrane review. For this update, we searched the Cochrane Library (2021, Issue 6), MEDLINE (to April 2023), Embase (to April 2023), five other databases (to July 2021), and reference lists of articles, and contacted study authors.Selection CriteriaWe included studies that evaluated the diagnostic accuracy of naso- and orogastric tube placement confirmed by ultrasound visualization using X-ray visualization as the reference standard. We included cross-sectional studies and case-control studies. We excluded case series or case reports. We excluded studies if X-ray visualization was not the reference standard or if the tube being placed was a gastrostomy or enteric tube.Data Collection And AnalysisTwo review authors independently assessed the methodological quality and extracted data from each of the included studies. We contacted the authors of the included studies to obtain missing data. There were sparse data for specificity. Therefore, we performed a meta-analysis of only sensitivity using a univariate random-effects logistic regression model to combine data from studies that used the same method and echo window.Main ResultsWe identified 12 new studies in addition to 10 studies included in the earlier version of this review, totalling 1939 participants and 1944 tube insertions. Overall, we judged the risk of bias in the included studies as low or unclear. No study was at low risk of bias or low concern for applicability in every QUADAS-2 domain. There were limited data (152 participants) for misplacement detection (specificity) due to the low incidence of misplacement. The summary sensitivity of ultrasound on neck and abdomen echo windows were 0.96 (95% confidence interval (CI) 0.92 to 0.98; moderate-certainty evidence) for air injection and 0.98 (95% CI 0.83 to 1.00; moderate-certainty evidence) for saline injection. The summary sensitivity of ultrasound on abdomen echo window was 0.96 (95% CI 0.65 to 1.00; very low-certainty evidence) for air injection and 0.97 (95% CI 0.95 to 0.99; moderate-certainty evidence) for procedures without injection. The certainty of evidence for specificity across all methods was very low due to the very small sample size. For settings where X-ray was not readily available and participants underwent gastric tube insertion for drainage (8 studies, 552 participants), sensitivity estimates of ultrasound in combination with other confirmatory tests ranged from 0.86 to 0.98 and specificity estimates of 1.00 with wide CIs. For studies of ultrasound alone (9 studies, 782 participants), sensitivity estimates ranged from 0.77 to 0.98 and specificity estimates were 1.00 with wide CIs or not estimable due to no occurrence of misplacement.Authors' ConclusionsOf 22 studies that assessed the diagnostic accuracy of gastric tube placement, few studies had a low risk of bias. Based on limited evidence, ultrasound does not have sufficient accuracy as a single test to confirm gastric tube placement. However, in settings where X-ray is not readily available, ultrasound may be useful to detect misplaced gastric tubes. Larger studies are needed to determine the possibility of adverse events when ultrasound is used to confirm tube placement.Copyright © 2024 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…