• J. Cardiothorac. Vasc. Anesth. · Oct 2010

    Comparative Study

    Comparison of the endotracheal cardiac output monitor to thermodilution in cardiac surgery patients.

    • Timothy R Ball, Benjamin C Culp, Vivekkumar Patel, David F Gloyna, David P Ciceri, and William C Culp.
    • Division of Cardiothoracic Anesthesiology, The Texas A&M University System Health Sciences Center College of Medicine, Scott & White Memorial Hospital, Temple, TX 76508, USA. tball@swmail.sw.org
    • J. Cardiothorac. Vasc. Anesth. 2010 Oct 1;24(5):762-6.

    ObjectivesTo compare cardiac output (CO) measurements from a novel endotracheal bioimpedance cardiac output monitor device (ECOM; ConMed, Irvine, CA) to simultaneous pulmonary artery thermodilution (TD) CO.DesignProspective study.SettingOne academic hospital.ParticipantsForty volunteer patients undergoing cardiac surgery.InterventionsIntraoperative CO measurements.Measurements And Main ResultsSimultaneous comparative data points were collected from ECOM and TD at 4 periods: post-induction, post-sternotomy, post-cardiopulmonary bypass, and post-chest closure. The mean CO(TD) was compared with CO(ECOM) for each operative period then assessed for agreement by linear regression, Bland-Altman analysis, and percent error methods. There were 35 men (87.5%) with a mean age of 66 ± 10.7 years in the present study population. R values (p value) for the 4 time periods were 0.50 (0.002), 0.33 (0.035), 0.42 (0.007), and 0.48 (0.002). Bias and 95% limits of agreement in L/min were -0.11 (-2.40 to 2.18), 0.04 (-2.57 to 2.65), -0.06 (-2.86 to 2.74), and 0.02 (-2.42 to 2.45). Percent errors of the 4 time periods were 51%, 53%, 50%, and 48%.ConclusionsECOM did not adequately agree with TD in patients undergoing cardiac surgery.Copyright © 2010 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.