• Minerva anestesiologica · Jul 2024

    Clinical validation of the Air-Test for the non-invasive detection of perioperative atelectasis in children.

    • Patricio González-Pizarro, Cecilia M Acosta, Gabriela Alcaraz García-Tejedor, Gerardo Tusman, Carlos Ferrando, Lila Ricci, Marcela L Natal, and Fernando Suarez-Sipmann.
    • Department of Pediatric Anesthesia and Critical Care, La Paz Children's University Hospital, Madrid, Spain - patricio.gonzalez@salud.madrid.org.
    • Minerva Anestesiol. 2024 Jul 1; 90 (7-8): 635643635-643.

    BackgroundThe incidence of anesthesia-induced atelectasis in children is high and closely related to episodes of hypoxemia. The Air-Test is a simple maneuver to detect lung collapse. By a step-reduction in FiO2 to 0.21, a fall in pulse-oximetry hemoglobin saturation <97% unmasks the presence of collapse-related shunt in healthy lungs. The aim of this study was to validate the Air-Test as a diagnostic tool to detect perioperative atelectasis in children using lung ultrasound as a reference.MethodsWe first assessed the Air-Test in a retrospective cohort of 88 anesthetized children (Retrospective study) followed by a prospective study performed in 72 children (45 postconceptional weeks to 16 years old) using a similar protocol (Validation study). We analyzed the performance of the Air-Test to detect atelectasis by an operating characteristic curve (ROC) analysis, using lung ultrasound consolidation score as reference.ResultsPreoperative SpO2 was normal in both studies (retrospective 98.7±0.6%, validation 99.0±0.9%). The Air-Test, with a SpO2 cut point <97%, resulted positive in 67 patients in the retrospective study (SpO2 93.3±2.1%) and in 59 in the validation study (SpO2 94.9±1.8%); both P<0.0001. In the validation study, the Air-Test showed a sensitivity of 0.91 (95% CI 0.85-0.92), specificity of 1.00 (95% CI 0.84-1) and an area under the curve (AUC) of 0.98 (95% CI 0.97-1.00). AUC between both studies was similar (P=0.16).ConclusionsThe Air-Test is a noninvasive and accurate method to detect atelectasis in healthy anesthetized children. It can be used as a screening tool to individualize patients that can benefit from lung recruitment maneuvers.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.