- A A Safiullina, T M Uskach, O V Sapelnikov, M A Saidova, A A Ansheles, V B Sergienko, V A Amanatova, I R Grishin, D I Cherkashin, R S Akchurin, and S N Tereschenko.
- Chazov National Medical Research Center of Cardiology.
- Terapevt Arkh. 2024 Jul 30; 96 (7): 675682675-682.
AimTo evaluate the efficacy and safety of the advanced technique for positioning the endocardial electrodes of a cardiac contractility modulation (CCM) device.Materials And MethodsThe CCM system was implanted in 100 patients, of which 60 CCM electrodes were positioned in the most optimal zones of myocardial perfusion, in particular, in the zone of the minor focal-scar/fibrotic lesion (the Summed Rest Score of 0 to 1-2, the intensity of the radiopharmaceutical at least 30%), and in 40 patients according to the standard procedure. Before the implantation of the CCM system, 60 patients underwent tomography (S-SPECT) of the myocardium with 99mTc-methoxy-isobutyl-isonitrile at rest to determine the most optimal electrode positioning zones and 100 patients underwent transthoracic echocardiography at baseline and after 12 months to assess the effectiveness of surgical treatment.ResultsImproved ventricular electrode positioning technique is associated with the best reverse remodeling of the left ventricular myocardium, especially in patients with ischemic chronic heart failure, with less radiation exposure to the surgeon and the patient, and without electrode-related complications.ConclusionAt the preoperative stage, it is recommended to perform a synchronized single-photon emission computed tomography of the myocardium with 99mTc-methoxy-isobutyl-isonitrile at rest before implantation of the CCM device to assess the presence of scar zones/myocardial fibrosis in the anterior and inferior septal regions of the interventricular septum of the left ventricle, followed by implantation of ventricular electrodes in the zone of the minor scar/fibrous lesion, which will allow to achieve optimal stimulation parameters, increase the effectiveness of CCM therapy, reduce the radiation exposure on medical personnel and the patient during surgery.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.