• BMC anesthesiology · Jul 2024

    A retrospective study of the effects of a vasopressor bolus on systolic slope (dP/dt) and dynamic arterial elastance (Eadyn).

    • Alexa C Abdallah, Sang H Song, and Neal W Fleming.
    • Department of Anesthesiology, University of California, San Diego, CA, USA.
    • BMC Anesthesiol. 2024 Jul 29; 24 (1): 257257.

    BackgroundTo enhance the utility of functional hemodynamic monitoring, the variables systolic slope (dP/dt) and dynamic arterial elastance (Eadyn) are calculated by the Hypotension Prediction Index (HPI) Acumen® Software. This study was designed to characterize the effects of phenylephrine and ephedrine on dP/dt and Eadyn.MethodsThis was a retrospective, non-randomized analysis of data collected during two clinical studies. All patients required intra-operative controlled mechanical ventilation and had an indwelling radial artery catheter connected to an Acumen IQ sensor. Raw arterial pressure waveform data was downloaded from the patient monitor and all hemodynamic measurements were calculated off-line. The anesthetic record was reviewed for bolus administrations of either phenylephrine or ephedrine. Cardiovascular variables prior to drug administration were compared to those following vasopressor administrations. The primary outcome was the difference for dP/dt and Eadyn at baseline compared with the average after the bolus administration. All data sets demonstrated non-normal distributions so statistical analysis of paired and unpaired data followed the Wilcoxon matched pairs signed-rank test or Mann-Whitney U test, respectively.Results201 doses of phenylephrine and 100 doses of ephedrine were analyzed. All data sets are reported as median [95% CI]. Mean arterial pressure (MAP) increased from 62 [54,68] to 78 [76,80] mmHg following phenylephrine and from 59 [55,62] to 80 [77,83] mmHg following ephedrine. Stroke volume and cardiac output both increased. Stroke volume variation and pulse pressure variation decreased. Both drugs produced significant increases in dP/dt, from 571 [531, 645] to 767 [733, 811] mmHg/sec for phenylephrine and from 537 [509, 596] to 848 [779, 930] mmHg/sec for ephedrine. No significant changes in Eadyn were observed.ConclusionBolus administration of phenylephrine or ephedrine increases dP/dt but does not change Eadyn. dP/dt demonstrates potential for predicting the inotropic response to phenylephrine or ephedrine, providing guidance for the most efficacious vasopressor when treating hypotension.Trial RegistrationData was collected from two protocols. The first was deemed to not require written, informed consent by the Institutional Review Board (IRB). The second was IRB-approved (Effect of Diastolic Dysfunction on Dynamic Cardiac Monitors) and registered on ClinicalTrials.gov (NCT04177225).© 2024. The Author(s).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…