    IntroductionNoise-Induced Hearing Loss (NIHL) is a condition caused by repeated exposure to loud noise, with operating theatre personnel potentially at risk. The aims of this study were to establish the typical noise levels in orthopaedic theatres and to compare these to The Control of Noise at Work Regulations 2005.Materials And MethodsWe measured the average noise levels in 40 trauma and orthopaedic surgeries in a single centre. We used the Decibel X app to take measurements, then performed corrections to ascertain noise levels at the surgeon's ear (Leq). The daily noise exposure level for theatre staff for each procedure (LEP, d) and the LEP, d over an average 8-hour working day when performing different groups of procedures were calculated. Data were analysed using descriptive statistics, ANOVA, t-test and the Pearson coefficient of correlation.ResultsThe LEP, d lower action value (80 dBA) as set by the Health and Safety Executive (HSE) was met by performing a single revision total knee replacement or a right open ankle debridement. Assuming three procedures are conducted per list, lists consisting of joint replacements (82 dBA) or medium elective procedures (81 dBA) exceed this lower limit. Additionally, lists comprising large and medium bone fractures would be within 1 dB of the limit (79 dBA and 79 dBA, respectively). Soft tissue (74 dBA), arthroscopic (73 dBA), and small bone fracture (71 dBA) procedures had the lowest LEP, d. The greatest contributors to noise levels were surgical instruments. The number of people in the room made a significant difference to noise levels (p = 0.032).ConclusionsWe have established the baseline noise levels in various orthopaedic procedures. Measures should be taken to meet UK regulations. Further research should determine suitable measures for protection from hearing damage for theatre staff and evaluate the risks high noise levels pose to patients.© 2024. The Author(s).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…