• Military medicine · Aug 2024

    Monitoring Respiratory Rate Continuously Without Attaching a Sensor During a Challenging Ramped Protocol.

    • Ulf R Borg, André Antunes, Philip Smit, Paul S Addison, and Dean Montgomery.
    • Medical Affairs, Medtronic Patient Monitoring, Boulder, CO 80301, USA.
    • Mil Med. 2024 Aug 19; 189 (Suppl 3): 618623618-623.

    IntroductionRespiratory rate (RR) is a crucial vital sign in patient monitoring and is often the best marker of the deterioration of a sick patient. It can be used to help diagnose numerous medical conditions and has been demonstrated to be an independent predictor of patient outcomes in various critical care settings and is incorporated in many clinical early warning scores. Here, we report on the performance of depth-camera-based system for the noncontact monitoring of RR during a ramped RR protocol. The ramped breathing protocol was developed specifically to test the relatively rapid changes in rates, which include clinically important low and high ranges of RRs.Materials And MethodsWe performed a series of experimental runs with healthy volunteers who were instructed to breathe over a wide range of RRs, where the rates were ramped up from 4 breaths/min to 50 breaths/min then back down to 4 breaths/min in a series of ramped steps. Depth information was acquired from the scene and used to determine a respiratory rate (RRdepth), and this was compared to capnograph or spirometer respiratory rate reference (RRref). A total of 9,482 contemporaneous data pairs (RRdepth, RRref) were collected during the study for comparison.ResultsA Pearson correlation coefficient of 0.995 was achieved and a line of best fit given by RRdepth = 0.99 × RRref + 0.36 breaths/min. The overall root mean squared difference (RMSD) across the runs was 1.29 breaths/min with a corresponding bias of 0.16 breaths/min, respectively. The associated Bland-Altman analysis found limits of agreement of -2.45 and 2.75 breaths/min. When the data were subdivided according to low, medium, and high RRs, corresponding to ≤10, >10 to 20, and >20 breaths/min, the RMSD accuracies were found to be 0.94, 1.34, and 1.55 breaths/min, respectively.ConclusionsThe technology performed well, exhibiting an RMSD accuracy well within our target of 3 breaths/min, both across the whole range and across each individual subrange. In summary, our results indicate the potential viability of continuous noncontact monitoring for the determination of RR over a clinically relevant range.Published by Oxford University Press on behalf of the Association of Military Surgeons of the United States 2024. This work is written by (a) US Government employee(s) and is in the public domain in the US.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.