• Eur J Trauma Emerg Surg · Aug 2024

    Compressive effect and collapse behavior of three different transsacral implants in sacral fragility fractures - a retrospective analysis of 106 cases.

    • C Fischer, F Klauke, P Schenk, H Bauerfeld, P Kobbe, and T Mendel.
    • Department of Trauma and Reconstructive Surgery, BG Klinikum Bergmannstrost Halle gGmbH, Merseburger Strasse 165, 06120, Halle (Saale), Germany. christian.fischer@bergmannstrost.de.
    • Eur J Trauma Emerg Surg. 2024 Aug 27.

    PurposeThe aim of this study were the retrospective evaluation of the compressive effect and complication rates of transsacral stabilization of osteoporosis-associated sacral fragility fractures in 106 patients using three different implants (6.0 mm sacral bar, n = 32; 7.3 mm screw, n = 26; 7.5 mm ISG-Rod System, n = 48) with regard to the image morphological and clinical-perioperative outcome.MethodsFor this purpose, the sacral width was determined preoperatively and postoperatively using multiplanar CT reconstructions and correlated with the measured bone density (HU). The results were compared with each other on an implant-specific basis.ResultsA significant compressive effect was found for all implants (6.0 mm sacral bar 7.1 ± 3.4 mm, 7.3 mm screw 6.9 ± 1.8 mm, 7.5 mm ISG-Rod System 8 ± 2.4 mm). No implant-specific difference in compression could be detected. Overall, the washers broke into the iliac cortex in 9% of cases. The subgroups did not differ significantly in this respect (6.0 mm sacral bar: 4 [13%], 7.3 mm screw 1 [1%], 7.5 mm ISG-Rod System (5 [10%], p = 0.581). A correlation between the degree of osteoporosis and the compressive effect could not be demonstrated. Significant implant-specific differences were found in the incision-suture time, with only ø0:39 ± 0:13 h required for implantation of the 7.5 mm ISG Rod System (6.0 mm sacral bar: ø1:09 ± 0:22 h, 7.3 mm screw: ø0:55 ± 0:20 h). The fluoroscopy time was significantly lower with the 7.3 mm screw (ø0:57 ± 0:23 min) and the 7.5 mm ISG Rod System (ø0:42 ± 00:17 min) than with the 6.0 mm sacral bar (ø1:36 ± 0:46 min).ConclusionA significant compressive effect was demonstrated with all three implants. No implant-specific complications or surgical site complications were identified in either the overall cohort or the subgroups. The 7.5 mm ISG Rod System shows advantages with regard to the duration of surgery and fluoroscopy.© 2024. The Author(s).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.