• Military medicine · Sep 2024

    A Deployable Viscoelastic Coagulation Monitor Enables Point-of-Care Assessment of Coagulopathy in Swine With Polytrauma.

    • Teryn R Roberts, Isabella Garcia, Ivan Slychko, Heidi J Dalton, and Andriy I Batchinsky.
    • Autonomous Reanimation and Evacuation Research Institute, The Geneva Foundation, San Antonio, TX 78235, USA.
    • Mil Med. 2024 Sep 12.

    IntroductionAbsence of pre-hospital coagulation tests challenges prompt management of hemostasis after trauma. The Viscoelastic Coagulation Monitor (VCM, Entegrion, Durham, NC) is a hand-held coagulation test for point-of-care. We evaluated VCM in a translational swine polytrauma model, hypothesizing that VCM correlates with a laboratory reference method, the TEG 5000 (Haemonetics, Boston, MA), and can identify coagulopathic phenotypes relevant to trauma. Our secondary hypothesis was that pre-warming of VCM disposable test cartridges using a heating plate versus pre-warming of cartridges by carrying the cartridge in the user's pocket does not significantly alter results.Materials And MethodsThis study was conducted in tandem with a parent study involving anesthetized, mechanically ventilated swine (n = 20; 54 ± 5 kg) that encountered traumatic brain injury, pulmonary contusion and hemorrhage, or combination/polytrauma injury. Blood was collected at baseline, post-injury, post-shock, post-transfusion, and 6-, 24-, and 48 h post-injury to perform VCM at point-of-care. Within-group effect of time was assessed. Spearman correlation examined linear relations between VCM and standard laboratory-based coagulation tests; as well as lactate, ionized calcium, and body temperature. Logistic regression examined predictiveness of VCM to identify coagulopathic phenotypes, with receiver operator characteristic curves generated to assess diagnostic capability. At a subset of timepoints, necessity of pre-warming the VCM test cartridge using a heating plate versus pre-warming the cartridge by placement in the user's pocket was assessed by conducting simultaneous tests on two separate instruments, with results analyzed by paired t-test with crossover design.ResultsVCM revealed time-dependent changes in clotting time, clot formation time (CFT), alpha, maximum clot firmness (MCF), and lysis index (LI30). All VCM metrics correlated with the respective TEG 5000 metrics, with strongest correlation for VCM MCF with TEG MA (rhos = 0.77, P < .0001) and VCM LI30 with TEG LY30 (rhos = -0.76, P < .0001). VCM demonstrated good (area under the curve >0.70) to excellent (area under the curve >0.90) diagnostic accuracy in detection of low platelet count (MCF), low hematocrit (clotting time, clot formation time, alpha, and MCF), low fibrinogen (MCF), and high fibrinogen (alpha, MCF). There was no statistically or clinically relevant effect of cartridge warming method on results.ConclusionsIn a trauma model, VCM detected significant changes in coagulation at point-of-care in a simplified portable form factor. VCM could enable informed hemostasis management in pre-hospital settings where coagulations tests are unavailable, pending further validation in clinical trials.© The Association of Military Surgeons of the United States 2024. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site–for further information please contact journals.permissions@oup.com.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…