• Plos One · Jan 2014

    The application of transcutaneous CO2 pressure monitoring in the anesthesia of obese patients undergoing laparoscopic bariatric surgery.

    • Shijiang Liu, Jie Sun, Xing Chen, Yingying Yu, Xuan Liu, and Cunming Liu.
    • Department of Anesthesiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
    • Plos One. 2014 Jan 1;9(4):e91563.

    AbstractTo investigate the correlation and accuracy of transcutaneous carbon dioxide partial pressure (PTCCO2) with regard to arterial carbon dioxide partial pressure (PaCO2) in severe obese patients undergoing laparoscopic bariatric surgery. Twenty-one patients with BMI>35 kg/m(2) were enrolled in our study. Their PaCO2, end-tidal carbon dioxide partial pressure (PetCO2), as well as PTCCO2 values were measured at before pneumoperitoneum and 30 min, 60 min, 120 min after pneumoperitoneum respectively. Then the differences between each pair of values (PetCO2-PaCO2) and. (PTCCO2-PaCO2) were calculated. Bland-Altman method, correlation and regression analysis, as well as exact probability method and two way contingency table were employed for the data analysis. 21 adults (aged 19-54 yr, mean 29, SD 9 yr; weight 86-160 kg, mean 119.3, SD 22.1 kg; BMI 35.3-51.1 kg/m(2), mean 42.1,SD 5.4 kg/m(2)) were finally included in this study. One patient was eliminated due to the use of vaso-excitor material phenylephrine during anesthesia induction. Eighty-four sample sets were obtained. The average PaCO2-PTCCO2 difference was 0.9 ± 1.3 mmHg (mean ± SD). And the average PaCO2-PetCO2 difference was 10.3 ± 2.3 mmHg (mean ± SD). The linear regression equation of PaCO2-PetCO2 is PetCO2 = 11.58+0.57 × PaCO2 (r(2) = 0.64, P<0.01), whereas the one of PaCO2-PTCCO2 is PTCCO2 = 0.60 + 0.97 × PaCO2 (r(2) = 0.89). The LOA (limits of agreement) of 95% average PaCO2-PetCO2 difference is 10.3 ± 4.6 mmHg (mean ± 1.96 SD), while the LOA of 95% average PaCO2-PTCCO2 difference is 0.9 ± 2.6 mmHg (mean ± 1.96 SD). In conclusion, transcutaneous carbon dioxide monitoring provides a better estimate of PaCO2 than PetCO2 in severe obese patients undergoing laparoscopic bariatric surgery.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.