-
Paediatric anaesthesia · Dec 2024
Assessment of accuracy of two pulse oximeters in infants with cyanotic and acyanotic congenital heart diseases.
- Yordan Hristov Georgiev, Felix Neunhoeffer, Michael Hofbeck, and Jörg Michel.
- Department of Pediatric Cardiology, Pulmonology and Pediatric Intensive Care Medicine, University Children's Hospital Tübingen, Tübingen, Germany.
- Paediatr Anaesth. 2024 Dec 1; 34 (12): 126712741267-1274.
BackgroundPeripherally measured oxygen saturation (SpO2) may often differ from arterial oxygen saturation (SaO2), measured by co-oximetry, especially within the lower range of oxygen saturations. This can potentially impact clinical decisions and therapy in children with congenital heart disease, as critical hypoxemia might remain unnoticed.AimsOur aim was to investigate the accuracy of two different pulse oximeters compared to SaO2 in infants with congenital heart diseases.MethodsSimultaneous recordings of SpO2, measured by two different pulse oximeters (Philips IntelliVue X3 Monitor and Nellcor™ OxiMax™), were compared to SaO2 obtained by arterial blood gas analysis.ResultsA total of 153 measurements were performed in 44 infants with arterial oxygen saturation between 70 and 100%. We divided the measurements into 3 subgroups: group 1-SaO2 70.0%-85.0%, group 2-SaO2 85.1%-94.0%, group 3-SaO2 >94.1%. For Philipps, the median bias was 5.3 (IQR: 2.6-8.7) %, 2.3 (IQR: 0.9-6.0) % and 1.1 (IQR: -0.8-2.4) % in group 1, 2 and 3, respectively. For OxiMax™, the median bias was 2.7 (IQR: 0.5-5.1) %, 0.2 (IQR: -0.9-2.6) % and -0.5 (IQR: -1.3-0.6) % in group 1, 2 and 3, respectively. Regarding the accuracy of these oximeters, as evaluated with the Accuracy root mean squared index (Arms), it was 9.8 versus 4.5% in group 1, 4.5 versus 2.9% in group 2 and 2.4 versus 1.9% in group 3 for Philipps and OxiMax™, respectively.ConclusionsIn lower range saturations between 70% and 85% the accuracy of both pulse oximeters exceeded the threshold of ≤3% recommended by the Food and Drug Administration (FDA). Therefore, peripheral pulse oximetry within the lower range of oxygen saturations should be interpreted with caution in infants with congenital heart diseases, taking into consideration its limitations. Direct co-oximetry should be the preferred method to support clinical decisions in children with cyanotic congenital heart diseases.© 2024 The Author(s). Pediatric Anesthesia published by John Wiley & Sons Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.