Randomized Controlled Trial
Application of placing the anterior end of endotracheal tube at the glottis in laryngeal mask airway positive ventilation during general anesthesia: A prospective, randomized, controlled trial.
- Zheng Chen, Xiao-Dong Ma, Zu-Min Mao, Lei Chen, Yuan-Feng Chen, and Dong-Hua Shao.
- Department of Anesthesiology, The Affiliated People's Hospital of Jiangsu University, Zhenjiang, Jiangsu, China.
- Medicine (Baltimore). 2024 Sep 27; 103 (39): e39934e39934.
BackgroundGlottic contraction and closure causes ventilation obstruction and laryngeal mask airway (LMA) leakage during positive pressure ventilation using LMA. This study aimed to assess the effect of placing the anterior end of the endotracheal tube (ET) at the glottis through the LMA ventilation conduit on treating LMA leakage following glottic contraction and closure.MethodsIn this prospective, randomized, controlled trial, patients with non-minor surgery using LMA ventilation were randomly allocated to the i-gel group (group L) and the i-gel combined with ET group (group LE). The tip of ET was placed 2 cm under glottis guided by fiberoptic bronchoscope through i-gel ventilation conduit in group LE. The perioperative incidence of i-gel leakage, the changes of systolic blood pressure (SBP) and heart rate (HR) following artificial airway insertion, and adverse events were recorded.ResultsPerioperative i-gel leakage was observed in 7 of 48 patients (14.6%) in group L and 1 of 49 patients (2.0%) in group LE. There was significant difference in the incidence of leakage between the 2 groups (P = .031). SBP and HR after ET insertion in group LE increased significantly compared to those in group L (P < .05/5). The values of both SBP and HR after ET insertion did not exceed the basic values in group LE (P > .05/4). There were no significant differences in the incidence and severity of postoperative sore pain and hoarseness, cough during i-gel and ET removal between the 2 groups (P > .05).ConclusionPlacing the anterior end of ET at the glottis reduced LMA air leakage related to glottic contraction and closure in non-minor surgery. The ET placing had low stress response and did not significantly increase postoperative complications.Copyright © 2024 the Author(s). Published by Wolters Kluwer Health, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.