• J Clin Monit Comput · Oct 2024

    Wire-in-needle versus conventional syringe-on-needle technique for ultrasound-guided central venous catheter insertion in the internal jugular vein: the WIN randomized trial.

    • Kristen K Thomsen, Jovana Stekovic, Felix Köster, Alina Bergholz, Karim Kouz, Moritz Flick, Daniel I Sessler, Christian Zöllner, Bernd Saugel, and Leonie Schulte-Uentrop.
    • Department of Anaesthesiology, Center of Anaesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany. science.thomsen@gmail.com.
    • J Clin Monit Comput. 2024 Oct 14.

    PurposeThere are different techniques for ultrasound-guided central venous catheter (CVC) insertion. When using the conventional syringe-on-needle technique, the syringe needs to be removed from the needle after venous puncture to pass the guidewire through the needle into the vein. When, alternatively, using the wire-in-needle technique, the needle is preloaded with the guidewire, and the guidewire-after venous puncture-is advanced into the vein under real-time ultrasound guidance. We tested the hypothesis that the wire-in-needle technique reduces the time to successful guidewire insertion in the internal jugular vein compared with the syringe-on-needle technique in adults.MethodsWe randomized 250 patients to the wire-in-needle or syringe-on-needle technique. Our primary endpoint was the time to successful guidewire insertion in the internal jugular vein.ResultsTwo hundred and thirty eight patients were analyzed. The median (25th percentile, 75th percentile) time to successful guidewire insertion was 22 (16, 38) s in patients assigned to the wire-in-needle technique and 25 (19, 34) s in patients assigned to the syringe-on-needle technique (estimated location shift: 2 s; 95%-confidence-interval: - 1 to 5 s, p = 0.165). CVC insertion was successful on the first attempt in 103/116 patients (89%) assigned to the wire-in-needle technique and in 113/122 patients (93%) assigned to the syringe-on-needle technique. CVC insertion-related complications occurred in 8/116 patients (7%) assigned to the wire-in-needle technique and 19/122 patients (16%) assigned to the syringe-on-needle technique.ConclusionThe wire-in-needle technique-compared with the syringe-on-needle technique-did not reduce the time to successful guidewire insertion in the internal jugular vein. Clinicians can consider either technique for ultrasound-guided CVC insertion in adults.© 2024. The Author(s).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…