• J Clin Monit Comput · Oct 2024

    Train-of-four ratio, counts and post tetanic counts with the Tetragraph electromyograph in comparison to mechanomyography.

    • Thomas J Ebert, Julia A Vogt, Roopvir Kaur, Zafar Iqbal, Douglas J Peters, Craig E Cummings, and Thomas A Stekiel.
    • Department of Anesthesiology, Medical College of Wisconsin, Milwaukee, WI, USA. tjebert@mcw.edu.
    • J Clin Monit Comput. 2024 Oct 18.

    AbstractAutomated EMG devices to detect compound muscle action potentials from the adductor pollicis muscle in response to ulnar nerve stimulation, regardless of hand and thumb position, may serve as a better reference ("gold standard") for clinical assessment of neuromuscular function than traditional mechanomyography (MMG) systems that need custom design and validation in lab settings. This evaluation compared the TetraGraph EMG system against a validated MMG device to investigate the accuracy and repeatability of this quantitative EMG monitor for detecting onset, offset and deep neuromuscular block. Simultaneous muscle action potential recordings from the EMG neuromuscular monitor and muscle contractions from an in-house developed MMG monitor in response to ulnar nerve stimulation were obtained from patients having elective surgery requiring neuromuscular block. Train-of-four (TOF) ratios, TOF counts, and post-tetanic counts (PTCs) were recorded simultaneously from the same hand muscle and compared. In total, 685 pairs of simultaneous TOF ratios were evaluated. The mean difference (bias) of TOF ratios between devices was small (- 2.1%). TOF counts from 285 data pairs were within a count of 2 or less 96% of the time. During deep block, PTC comparisons from 215 data pairs were within a count of 2 or less 95% of the time. These findings, along with prior EMG device evaluations, indicate that real-time EMG neuromuscular monitoring technology to detect muscle action potentials from the adductor pollicis in the clinical setting is closely aligned with the force of thumb contraction determined from MMG. The accuracy of quantitative EMG technology of the TetraGraph EMG system lends strong support for this monitor, along with other similarly validated EMG monitors, to become a clinical standard for all phases (onset, depth and reversal) of neuromuscular block in clinical practice.© 2024. This is a U.S. Government work and not under copyright protection in the US; foreign copyright protection may apply.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…