• Der Anaesthesist · Jul 1995

    Clinical Trial

    [Continuous measurement of cardiac output with pulse contour analysis].

    • M Irlbeck, H Forst, J Briegel, M Haller, and K Peter.
    • Institut für Anaesthesiologie, Ludwig-Maximilians-Universität München.
    • Anaesthesist. 1995 Jul 1; 44 (7): 493-500.

    AbstractPulse contour cardiac output (PCCO) is an easily applicable method for continuous measurement of cardiac output in critically ill patients. Calculation of stroke volume is possible by analysing the area under the systolic part of the arterial pulse pressure waveform together with an individual calibration factor (Zao) to account for the individually variable vascular impedance. Since vascular impedance is potentially affected by altered vascular tone, it was the aim of the present study to examine the validity of PCCO in ICU patients receiving various dosages of a variety of vasoactive drugs. PATIENTS AND METHODS. Continuous cardiac output was measured in 20 ICU patients for a total of 110 h using the pulse contour method. The precision of PCCO was determined in comparison with its calibration reference, the thermodilution method (TDCO): (1) during administration of vasoactive drugs at a constant rate and (2) during conditions with altered vascular tone and haemodynamics elicited by changes in vasoactive drug dosage. For this purpose, the patients received varying dosages of vasoactive drugs (dopamine, dobutamine, epinephrine, norepinephrine, nitroglycerin, prostacyclin and urapidil). RESULTS. A total of 165 data sets was obtained, each consisting of the average of four capnometrically triggered TDCO measurements and the corresponding PCCO values. The relative difference between methods (+/- 2 SD) was +/- 23.9% (SD 0.85 l.min-1; r = 0.93) if a single calibration at the beginning of measurement series was performed (Fig. 2). The bias of the mean cardiac output values of both methods was -0.09 l.min-1. The precision of PCCO improved to +/- 15.7% by additional calibrations (SD 0.56.min-1; r = 0.96; bias 0.003 l.min-1). Data of two patients showed that recalibration may be necessary after extreme haemodynamic changes due to septic shock or cooling. Alteration of vascular tone by clinically used dosage of vasoactive drugs, however, had no destabilizing effect on the pulse contour method. CONCLUSIONS. It could be demonstrated that PCCO provides a valuable method for continuous cardiac output measurement in the intensive care setting with a precision comparable to that of thermodilution.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…