• Lancet · Nov 2024

    Randomized Controlled Trial Multicenter Study Comparative Study

    Bioadaptor implant versus contemporary drug-eluting stent in percutaneous coronary interventions in Sweden (INFINITY-SWEDEHEART): a single-blind, non-inferiority, registry-based, randomised controlled trial.

    • David Erlinge, Jonas Andersson, Ole Fröbert, Mattias Törnerud, Mehmet Hamid, Thomas Kellerth, Per Grimfjärd, Oscar Winnberg, Juliane Jurga, Henrik Wagner, Sammy Zwackman, Martin Adielsson, Patrik Alström, Elli Masoe, Anders Ulvenstam, Jonas Millgård, Felix Böhm, Claes Held, Henrik Renlund, Jonas Oldgren, Pieter C Smits, Candace Elek, Andrea Abizaid, and Stefan James.
    • Department of Cardiology, Clinical Sciences, Lund University, Skåne University Hospital, Lund, Sweden. Electronic address: david.erlinge@med.lu.se.
    • Lancet. 2024 Nov 2; 404 (10464): 175017591750-1759.

    BackgroundPersistent non-plateauing adverse event rates in patients who underwent percutaneous coronary intervention (PCI) remain a challenge. A bioadaptor is a novel implant that addresses this issue by restoring the haemodynamic modulation of the artery, allowing cyclic pulsatility, vasomotion, and adaptative remodelling, by unlocking and providing dynamic support to the artery. We aimed to assess outcomes with the device versus a contemporary drug-eluting stent (DES) in a representative PCI population.MethodsINFINITY-SWEDEHEART is a single-blind, non-inferiority, registry-based, randomised controlled study conducted in 20 hospitals in Sweden. Patients aged 18-85 years, with chronic or acute coronary syndrome ischaemic heart disease, with an indication for PCI, with up to three de novo lesions suitable for implantation with one single device per lesion, and successful pre-dilatation were identified via the Swedish Coronary Angiography and Angioplasty Registry and eligible for enrolment. Participants were randomly assigned (1:1), using block randomisation with random variation in block size and stratified by site, to either the DynamX bioadaptor (Elixir Medical, Milpitas, CA, USA) or a zotarolimus-eluting DES (Resolute Onyx and Onyx Trustar, Medtronic, Minneapolis, MN, USA). The primary endpoint was the device-oriented clinical endpoint of target lesion failure at 12 months (a composite of cardiovascular death, target vessel myocardial infarction, and ischaemia-driven target lesion revascularisation), assessed in the intention-to-treat (ITT) population (ie, all patients randomly assigned to treatment, regardless of treatment received) who had either experienced an event up to 12 months or completed the trial up to 12 months. Non-inferiority was established if the upper limit of the two-sided 95% CI for the absolute risk difference was less than 4·2%. Powered secondary endpoints were landmark analyses from 6 months onwards for target lesion failure, target vessel failure (composite of cardiovascular death, target vessel myocardial infarction, and ischaemia-driven target vessel revascularisation), and target lesion failure for patients with acute coronary syndrome assessed in the ITT population). This study is registered with ClinicalTrials.gov, NCT04562805, and follow-up to 5 years is ongoing.FindingsBetween Sept 30, 2020, and July 11, 2023, 2399 patients were randomly assigned to receive the bioadaptor (n=1201) or DES (n=1198; ITT population). Median age was 69·5 years (IQR 61·2-75·6), 575 (24·0%) of 2399 patients were female, and 1824 (76·0%) were male (data on race and ethnicity were not collected), and 1838 (76·6%) patients presented with acute coronary syndrome. The primary endpoint of 12-month target lesion failure occurred in 28 (2·4%) of 1189 assessable patients in the bioadaptor group versus 33 (2·8%) of 1192 assessable patients in the DES group, with a risk difference of -0·41% (95% CI -1·94 to 1·11; pnon-inferiority<0·0001). In the prespecified landmark analysis from 6 months to 12 months, the Kaplan-Meier estimates of target lesion failure were 0·3% (with events in three of 1170 patients) in the bioadaptor group versus 1·7% (with events in 16 of 1176 patients) in the DES group (hazard ratio 0·19 [95% CI 0·06 to 0·65]; p=0·0079), of target vessel failure were 0·8% (events in eight of 1167) versus 2·5% (events in 23 of 1174; 0·35 [0·16 to 0·79]; p=0·011), and of target lesion failure in patients with acute coronary syndrome were 0·3% (events in two of 906) versus 1·8% (events in 12 of 895; 0·17 [0·04 to 0·74]; p=0·018). The rate of definite or probable device thrombosis, which was recorded as a safety outcome, was low and did not differ between groups (eight [0·7%] of 1201 in the bioadaptor group vs six [0·5%] of 1198 in the DES group; difference in event rates of 0·16% [95% CI -0·50 to 0·83]).InterpretationAmong patients with coronary artery disease, including those with acute coronary syndrome, treatment with the bioadaptor was non-inferior to contemporary DES, showing potential to mitigate non-plateauing device-related events and improving outcomes in patients undergoing PCI. The additional planned follow-up will help to reinforce the clinical significance of the 1-year findings.FundingElixir Medical.Copyright © 2024 Elsevier Ltd. All rights reserved, including those for text and data mining, AI training, and similar technologies.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.