• Singapore medical journal · Nov 2024

    Long-term clinical outcomes of remote monitoring for implantable cardioverter-defibrillators in Singapore.

    • Vern Hsen Tan, Khi Yung Fong, Lisa Jie Ting Teo, Deborah Wai Yi Lo, Fiona Wan Qi Ku, Yiong Huak Chan, Yue Wang, Colin Yeo, Chi Keong Ching, and Toon Wei Lim.
    • Department of Cardiology, Changi General Hospital, Singapore.
    • Singapore Med J. 2024 Nov 5.

    IntroductionRemote monitoring (RM) for cardiac implantable electronic devices is on the rise and has been shown to reduce the burden of in-clinic follow-up visits. We aimed to investigate the long-term clinical outcomes of RM versus no RM.MethodsThis was a prospective, single-centre cohort study of consecutive patients with an implantable cardioverter-defibrillator (ICD) or cardiac resynchronisation therapy-defibrillator (CRT-D) followed up from 2018 to 2023. Patients who received non-ICD devices were excluded. In general, RM was offered to all patients, but uptake depended on patient preference. For data analysis, patients were stratified according to whether RM was used. The primary outcome was all-cause mortality; secondary outcomes were hospitalisation for heart failure and device therapy (shocks and electrical storm).ResultsOf 551 patients, 284 (51.5%) received RM and 267 (49.5%) did not. Baseline demographics were similar between the two arms. All-cause mortality was significantly lower in RM versus non-RM patients (hazard ratio [HR] 0.45, 95% confidence interval [CI] 0.33-0.60, P <0.001), as was hospitalisation for heart failure (HR 0.39, 95% CI 0.25-0.59, P <0.001); these remained significant after adjustment for baseline covariates. More patients on RM received appropriate antitachycardia pacing (ATP) (17.6% vs. 10.7%, P = 0.035) and appropriate shocks (24.1% vs. 14.7%, P = 0.017). The incidences of inappropriate ATP, inappropriate shocks and electrical storm were similar. More patients on RM underwent pulse generator change (34.1% vs. 10.1%, P <0.001).ConclusionRemote monitoring was associated with significantly lower mortality in both ICDs and CRT-Ds and in primary and secondary indications, as well as fewer heart failure hospitalisations. This supports current guidelines recommending the use of RM in all patients with ICD or CRT-D.Copyright © 2024 Copyright: © 2024 Singapore Medical Journal.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.