• Injury · Oct 2024

    An early analysis of polyetheretherketone (PEEK) plates for the surgical stabilization of rib fractures: A pilot study.

    • Zachary M Bauman, Yuqian Tian, Gregory Puthoff, Sarah Ann Whitbeck, Scott Gardner, and Thomas W White.
    • Division of Trauma, Emergency General Surgery and Critical Care Surgery, Department of Surgery, University of Nebraska Medical Center, Omaha, NE, USA. Electronic address: zachary.bauman@unmc.edu.
    • Injury. 2024 Oct 20; 55 (12): 111969111969.

    BackgroundSurgical stabilization of rib fractures (SSRF) is a viable treatment option for rib fracture patients. Polyetheretherketone (PEEK) plates have become available for SSRF. The objective of this pilot study was to examine the use of PEEK plates for SSRF.MethodsA prospective, observational, multi-center study of patients undergoing SSRF with PEEK plates from 4/23 through 2/24. Standard indications for SSRF were followed and the decision to use PEEK plates was left to the discretion of the treating surgeon. Basic demographics were obtained. Outcomes included the number of rib fractures stabilized with PEEK plates, complications related to SSRF, and 6-month follow-up with chest computed tomography (CT) to assess healing of PEEK repaired fracture sites, identified as complete or incomplete union. Patients also answered a five-question quality-of-life survey regarding mobility, self-care, usual activities, chest pain/discomfort, and anxiety/depression. Answers were scaled 1 to 5 (1=worse condition possible; 5=best possible condition). Patients rated their health on a scale of 0 to 100 (100=closet to their health preinjury). All data was reported as descriptive.ResultsForty-six patients were included. Average age was 57(±16) years; 82.6 % were male. Median ISS was 18 (IQR 14,29) and median chest-AIS was 4 (IQR 3,4). 219 rib fractures were stabilized with PEEK plates. Sixteen (34.8 %) had a combination (PEEK + titanium) procedure. Three patients had a complication: one required a second surgery for additional SSRF, and two patients were readmitted. Twenty-seven patients were surveyed at 6 months, and 19 agreed to CT scan. Eighty PEEK repaired rib fractures were assessed for healing. 80 % of fractures had complete union and no hardware failure. Quality-of-life survey averaged >4.5/category and mean overall health was 89.ConclusionPEEK plates for SSRF are safe and effective, allowing for adequate rib fracture healing and are associated with positive patient reported outcomes.Copyright © 2024 Elsevier Ltd. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…