• BMC anesthesiology · Nov 2024

    Observational Study

    The evaluation of endotracheal tube cuff pressure in pediatric patients by subjective inflation techniques: a prospective observational study.

    • Darunee Sripadungkul, Nawaporn Tanasoontornsut, Prathana Wittayapairoch, Thitinuch Ruenhunsa, Peerapong Sangsungnern, Cattleya Kasemsiri, Nathee Maneewan, and Sutida Boonkamjad.
    • Department of Anesthesiology, Faculty of Medicine, Khon Kaen University, Khon Kaen, 40002, Thailand.
    • BMC Anesthesiol. 2024 Nov 5; 24 (1): 399399.

    BackgroundCuffed endotracheal tubes (ETTs) are commonly used in pediatric patients, with the gold standard for measuring cuff pressure being a cuff pressure manometer. However, this equipment is not always available in every operating room. Subjective inflation techniques, such as the minimal occluding volume (MOV) technique and the stethoscope-guided (Steth) technique, offer convenient and safe alternatives to standard methods but do not provide quantitative measurements. This study aimed to evaluate ETT cuff pressures and volumes of air inflated using the two subjective techniques (MOV and Steth) in pediatric patients.MethodsThis prospective observational study was conducted at the Department of Anesthesiology, Faculty of Medicine, Khon Kaen University, Thailand. We included healthy pediatric patients aged 2 to 7 years undergoing elective surgeries under general anesthesia with a cuffed ETT. The primary objective of this study was to compare the mean ETT cuff pressures and volumes of air inflated using the two subjective inflation techniques (MOV and Steth method). The secondary objectives include identifying factors associated with inappropriate inflation and evaluating post-intubation complications.ResultsSixty-four pediatric patients were analyzed. The overall mean ETT cuff pressure was 26.52 ± 8.68 cmH2O. The target was achieved in 46.88% of patients, with overinflation in 32.81% and underinflation in 20.31%. The mean ETT cuff pressure in the MOV group was 27.77 ± 8.89 cmH2O and in the Steth group was 25.33 ± 8.34 cmH2O, with a non-significant mean difference of 2.44 cmH2O (95% CI [-1.89, 6.77], p = 0.264). The mean volume of air inflated in the MOV group was 0.78 ± 0.25 ml, and in the Steth group was 0.68 ± 0.22 ml, with a non-significant mean difference of 0.10 ml (95% CI [-0.01, 0.22], p = 0.084). Younger age, lower weight, and shorter height were significantly associated with an increased risk of overinflation. An ETT size with an internal diameter (ID) of 5 mm was significantly associated with an increased risk of underinflation. No post-intubation complications were reported.ConclusionsSubjective inflation techniques (MOV or Steth) achieve target ETT cuff pressures in less than 50%, and carry the risks of both overinflation and underinflation, even without post-intubation complications.Trial RegistrationTCTR20211016001 (registered with the Thai Clinical Trials Registry on October 16, 2021).© 2024. The Author(s).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…