-
Comparative Study
Comparison of elective implant removal and complication rates between mini and small fragment implants for lateral malleolar fixation.
- Riley Swenson, Thomas Z Paull, Zachary A Rockov, Kevin Huang, Gaonhia Moua, LittleMilton T MMTMDepartment of Orthopaedic Surgery, Cedars Sinai Medical Center, Los Angeles, CA, USA., and Mai P Nguyen.
- Department of Orthopaedic Surgery, Regions Hospital, Saint Paul, MN, USA; Department of Orthopaedic Surgery, University of Minnesota Medical School, Minneapolis, MN, USA.
- Injury. 2024 Dec 1; 55 (12): 112014112014.
IntroductionImplant removal after open reduction and internal fixation (ORIF) of ankle fractures is common. Mini-fragment implants have gained popularity for their smaller size, with studies showing similar load to failure to small-fragment implants. We hypothesized mini-fragment implant use for ORIF of the distal fibula is associated with a lower implant removal rate and without an increase in implant failure.MethodsIn this retrospective review study at two level-one trauma centers, adult patients (>18 years) with a lateral malleolar or bimalleolar fracture were included. Chart review was performed to determine if patients received ORIF of the distal fibula with mini-fragment implants or small-fragment implants. The primary outcome was elective implant removal of the fibular plate. Secondary outcomes included complications requiring reoperation.ResultsFive-hundred and five patients were included with a mean age of 50.6 ± 17.8 years old with a mean follow-up of was 75.7 ± 61.0 weeks. Sixty patients (11.9 %) received mini-fragment fixation. The rate of elective distal fibula implant removal for the mini-fragment group was 8.3 % (5 of 60) compared to 10.8 % (48 of 445) in the small-fragment group (p = .66). The complication rate was 6.7 % (4 of 60) for the mini fragment group versus 6.5 % (29 of 445) for the small fragment group (p = 1.00). Logistic regression demonstrated that each additional week of follow-up increased the implant removal rate with the observed odd ratio (OR) of 1.007 (95 % CI 1.002-1.012).ConclusionElective implant removal rates and complications requiring reoperation were similar between mini-fragment and small-fragment fixation of distal fibula fractures. The hypothetical benefit of low-profile mini-fragment implants should be balanced with the higher implant cost.Copyright © 2024 Elsevier Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.