• Arch Orthop Trauma Surg · Dec 2024

    Impact of the difference between preoperative planning and intraoperative femoral neck osteotomy level on stem alignment.

    • Shuhei Ueno, Kentaro Iwakiri, Yoichi Ohta, Yukihide Minoda, Akio Kobayashi, and Hiroaki Nakamura.
    • Department of Orthopaedic Surgery, Shiraniwa Hospital Joint, Arthroplasty Center. 6-10-1 Shiraniwadai Ikoma-city, Nara, 630-0136, Japan.
    • Arch Orthop Trauma Surg. 2024 Dec 12; 145 (1): 2424.

    BackgroundThe combined anteversion theory is used for implant placement in total hip arthroplasty (THA). While majority of the research emphasizes the precise placement of the acetabular cup, there's less focus on stem alignment. This study aimed to investigate the impact of the discrepancy between the preoperatively planned femoral neck osteotomy level and the actual osteotomy level during surgery on stem alignment.Materials And MethodsThe study involved 232 patients (258 joints) who had a total hip arthroplasty (THA) between April 2018 and December 2022 at our hospital. They were implanted with either the ACTIS stem (Depuy Synthes) or Taperloc Complete XR 123° (Zimmer Biomet)-147 joints with ACTIS stem and 111 with Taperloc stem. Three-dimensional templating software was used to evaluate preoperative planning and postoperative stem placement angles. The difference between the actual and preoperatively planned osteotomy levels was also measured. The impact of this difference in femoral neck osteotomy level on stem alignment was evaluated.ResultsIn the ACTIS stem group, the femoral neck osteotomy level was - 0.3 ± 3.7 mm. The stem alignment had a varus of 1.8 ± 1.9°, extension of 0.1 ± 1.5°, and anteversion of 2.4 ± 5.9°, compared to preoperative plans. A positive correlation was identified between osteotomy level and varus/valgus alignment (r = 0.607, p < 0.01), with a weak correlation for anteversion (r = 0.236, p < 0.01). No correlation existed with flexion/extension. In the Taperloc stem group, osteotomy level was 2.2 ± 3.1 mm. The postoperative stem showed a varus of 1.6 ± 1.5°, extension of 0.5 ± 1.7°, and anteversion of 4.9 ± 6.5°. A correlation was observed between osteotomy level and varus/valgus alignment (r = 0.476, p < 0.01), but not with flexion/extension or anteversion.ConclusionsThe study examined how differences in planned vs. actual femoral neck osteotomy affect stem alignment in THA using ACTIS stem and Taperloc stem. We found that osteotomy level influenced varus/valgus alignment; mildly affected flexion/extension; and had no effect on anteversion.© 2024. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…