Acta Anaesthesiol Scand · Feb 2001
Clinical TrialMonitoring of end-tidal carbon dioxide partial pressure changes during infrarenal aortic cross-clamping: a non-invasive method to predict unclamping hypotension.
- G Boccara, S Jaber, J Eliet, C Mann, and P Colson.
- Department of Anesthesiology and Intensive Care, DAR-B, Medical University of Montpellier, France. gilles.boccara@psl.ap-hop-paris.fr
- Acta Anaesthesiol Scand. 2001 Feb 1;45(2):188-93.
BackgroundTo assess the variations in end-tidal CO2 in response to aortic cross-clamping and the relationship with systolic arterial pressure (SAP) changes induced by unclamping.MethodsThirty-three patients undergoing infrarenal aortic abdominal aneurysm repair by aorto-aortic prothetic bypass were prospectively studied. All patients were anesthetized with i.v. midazolam (0.05 mg x kg(-1)), thiopentone (3-5 mg x kg(-1)), fentanyl (5 microg x kg(-1)), pancuronium (0.1 mg x kg(-1)) and the maintainance of anesthesia used was 1-1.5% end-tidal isoflurane and i.v. fentanyl. The perioperative management was standardized. End-tidal CO2 and SAP were measured 5 min before (Pre-XAA), 15 min after infrarenal aortic cross-clamping (XAA), 5 min before (Pre-UXAA) and immediately after unclamping (UXAA).ResultsA total of 16 (48.5%) from 33 patients presented decrease in SAP following aortic unclamping, and 13 out of these patients had arterial hypotension defined as SAP<90 mmHg. End-tidal CO2 variation (PreXAA-PreUXAA) induced by aortic clamping was correlated with SAP variation (PreUXAA-UXAA) induced by unclamping (r=0.763; P=0.0001). An end-tidal CO2 reduction above 15% after aortic cross-clamping was found to have a 100% sensitivity to detect a SAP decrease greater than 20% after unclamping, with a 100% specificity and a negative predictive value of 1.0. Complete aortic occlusion duration was not correlated to SAP unclamping variation (deltaSAP). Intraoperative characteristics (fluid loading, hematocrits, urinary output) were comparable, although blood loss was higher in patients experiencing deltaSAP>20%.ConclusionsEnd-tidal CO2 variation monitoring during aortic cross-clamping may provide a reliable and non-invasive method to predict unclamping hypotension. When the aortic clamp was released, systolic hypotension (>20%) occurred in those subjects who had a decrease in end-tidal CO2 greater than 15% during aortic cross-clamping.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.