• Paediatric anaesthesia · Feb 2025

    Effect of infusion line connection and infusion line characteristics on start-up fluid delivery from syringe infusion pumps used for microinfusion.

    • Markus Weiss, Pedro David Wendel-Garcia, Vincenzo Cannizzaro, and Maren Kleine-Brueggeney.
    • Department of Anesthesia, University Children's Hospital, Zurich, Switzerland.
    • Paediatr Anaesth. 2025 Feb 1; 35 (2): 118124118-124.

    BackgroundConnecting an infusion line to a closed stopcock results in pressurization of fluid within the syringe infusion pump assembly leading to flow irregularities when opening the stopcock and activating the pump.AimsIt was the purpose of this study to assess the extent of pressurization under different conditions and its impact on start-up fluid delivery.MethodsIntraluminal pressures and start-up fluid delivery at 1 mL/h flow rate were assessed with connection of the infusion line 1 min (delayed connection) or immediately after purging (immediate connection) using two different infusion lines made from polyvinylchloride (PVC) or polyethylene (PE).ResultsDelayed connection resulted in an increase of intraluminal pressures from zero to 5.1 [4.5 to 5.7] mmHg with the PVC line and from zero to 47.1 [44.8 to 49.3] mmHg with the PE line (mean difference 42.0 [95% CI 39.3-44.7] mmHg; p < .0001). Immediate connection resulted in an increase of intraluminal pressures from zero to 44.3 [41.8-46.8] mmHg with the PVC line and from zero to 61.3 [57.2-65.4] mmHg with the PE line (mean difference 17.0 [95% CI 11.8-22.2] mmHg; p < .0001). The increase in intraluminal pressures was significantly higher with PE lines for both delayed and immediate connection when compared to the PVC lines (mean difference 29.5 [95% CI 19.3-39.7] mmHg; p < .0001). Related fluid volumes delivered at 10 s and 360 s after starting the pump ranged from -252% to 1321% (10 s) of expected infusion volumes and from 59% to 129% (360 s), respectively.ConclusionsBoth, timing of infusion line connection after purging and infusion line characteristics considerably affect intraluminal pressures and start-up fluid delivery when connecting a new syringe infusion pump assembly to a closed stopcock. Consecutive alterations in drug administration can have considerable hemodynamic consequences when dealing with catecholamine infusions in critically ill patients.© 2024 The Author(s). Pediatric Anesthesia published by John Wiley & Sons Ltd.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…