- Hui-Chih Wang, Wen-Chu Chiang, Shey-Ying Chen, Yi-Ling Ke, Chun-Lin Chi, Chih-Wei Yang, Pei-Ching Lin, Patrick Chow-In Ko, Yao-Cheng Wang, Tsung-Che Tsai, Chien-Hwa Huang, Kuan-Hwa Hsiung, Matthew Huei-Ming Ma, Shyr-Chyr Chen, Wen-Jone Chen, and Fang-Yue Lin.
- Department of Emergency Medicine, National Taiwan University Hospital, Taipei, Taiwan.
- Resuscitation. 2007 Sep 1;74(3):453-60.
IntroductionThe quality of cardiopulmonary resuscitation (CPR) plays a crucial role in saving lives from out-of-hospital cardiac arrest (OHCA). Previous studies have identified sub-optimal CPR quality in the prehospital settings, but the causes leading to such deficiencies were not fully elucidated.ObjectiveThis prospective study was conducted to identify operator- and ambulance-related factors affecting CPR quality during ambulance transport; and to assess the effectiveness of mechanical CPR device in such environment.Materials And MethodsA digital video-recording system was set up in two ambulances in Taipei City to study CPR practice for adult, non-traumatic OHCAs from January 2005 to March 2006. Enrolled patients received either manual CPR or CPR by a mechanical device (Thumper). Quality of CPR in terms of (1) adequacy of chest compressions, (2) instantaneous compression rates, and (3) unnecessary no-chest compression interval, was assessed by time-motion analysis of the videos.ResultsA total of 20 ambulance resuscitations were included. Compared to the manual group (n=12), the Thumper group (n=8) had similar no-chest compression interval (33.40% versus 31.63%, P=0.16); significantly lower average chest compression rate (113.3+/-47.1 min(-1) versus 52.3+/-14.2 min(-1), P<0.05), average chest compression rate excluding no-chest compression interval (164.2+/-43.3 min(-1) versus 77.2+/-6.9 min(-1), P<0.05), average ventilation rate (16.1+/-4.9 min(-1) versus 11.7+/-3.5 min(-1), P<0.05); and longer no-chest compression interval before getting off the ambulance (5.7+/-9.9s versus 18.7+/-9.1s, P<0.05). The majority of the no-chest compression interval was considered operator-related; only 15.3% was caused by ambulance related factors.ConclusionsMany unnecessary no-chest compression intervals were identified during ambulance CPR, and most of this was operator, rather than ambulance related. Though a mechanical device could minimise the no-chest compression intervals after activation, it took considerable time to deploy in a system with short transport time. Human factors remained the most important cause of poor CPR quality. Ways to improve the CPR quality in the ambulance warrant further study.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.