-
- Stefano Giovanazzi, Domenico Nocera, Giulia Catozzi, Francesca Collino, Massimo Cressoni, Lorenzo Ball, Onnen Moerer, Michael Quintel, Luigi Camporota, and Luciano Gattinoni.
- Department of Anesthesiology, University Medical Center Göttingen, Robert-Koch-Str 40, 37075, Göttingen, Germany. stefanogiovanazzi94@gmail.com.
- Crit Care. 2025 Feb 6; 29 (1): 6464.
AbstractAssessing and quantifying recruitability are important for characterizing ARDS severity and for reducing or preventing the atelectrauma caused by the cyclic opening and closing of pulmonary units. Over the years, several methods for recruitment assessment have been developed, grouped into three main approaches: 1) Quantitative CT Scanning: This method accurately measures the amount of atelectatic lung tissue that regains aeration; 2) Regional Gas Volume Measurement: Based on anatomical markers, this approach assesses gas volume within a specified lung region; 3) Compliance-Based Gas Volume Measurement: This technique compares actual gas volume at a given pressure to expected values, assuming respiratory system compliance is constant within the explored pressure range. Additional methods, such as lung ultrasonography and electrical impedance variation, have also been explored. This paper details the distribution of opening and closing pressures throughout the lung parenchyma, which underpin the concept of recruitability. The distribution of recruitable regions corresponds to atelectasis distribution, with the pressure needed for recruitment varying according to whether the atelectasis is "loose" or "sticky." We also discuss the effects of different PEEP levels on preventing atelectrauma, the importance of keeping some lung areas closed throughout the respiratory cycle, and briefly cover the roles of sigh ventilation, prone positioning, and the closed lung approach.© 2025. The Author(s).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.